Work

Dynamic corneal responses from successive tonometry at different resting intervals using the Corvis ST in young myopes

Year: 2026
Type: article
Study design: Observational Study
Abstract: Background To investigate the effects of successive measurements and resting intervals on dynamic corneal response (DCR) parameters obtained using corneal visualization Scheimpflug tonometry (Corvis ST). Methods This prospective repeated-measures observational study included young healthy myopes who underwent three successive Corvis ST measurements at four fixed intervals: 5 min (T5m), 2 min (T2m), 30 s (T30s), and immediate succession (Ti). Eleven DCR parameters were analyzed: first applanation time (A1T) and velocity (A1V), deformation amplitude (DA), highest concavity time (HCT), peak distance (PeakDist), deflection amplitude (DefleA), stiffness parameter at first applanation (SP-A1), and stress-strain index (SSI), deflection length at A1 (A1DefLen), deflection amplitude at A1 (A1DefAmp), and deflection area at A1 (A1DefArea). Linear mixed models with a random subject intercept were used to test the effects of successive measurements, intervals, and their interactions, adjusted for axial length (AL), biomechanically corrected intraocular pressure (bIOP), and central corneal thickness (CCT), with Sidak-adjusted post hoc comparisons. Results No interactions between successive measurements and intervals were detected for any parameter (all p > 0.11). Successive measurements significantly affected only DA (p = 0.001). The 2 nd measurement showed a slightly larger DA (+0.010 mm versus the first, p < 0.001). The interval significantly affected the DA (p = 0.005), HCT (p = 0.015), SP-A1 (p = 0.004), A1DefLen (p = 0.005), and A1DefAmp (p = 0.002). The largest adjusted differences were 0.01 mm (DA), 0.09 ms (HCT), 1.5 mmHg/mm (SP-A1), 0.028 mm (A1DefLen), and 0.001 mm (A1DefAmp). A longer AL was independently associated with a larger DefleA (p < 0.001) and PeakDist (p < 0.001). SSI was independent of successive measurements, intervals, bIOP, and CCT (all p > 0.11). Conclusion Corvis ST DCR parameters had only slight changes across successive measurements and different resting intervals from 5 min to no rest in young myopes. Averaging three Corvis ST measurements may be useful, regardless of the resting interval between acquisitions, although further studies are needed.
Language: English
Subfield: Ophthalmology
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,801
OpenAlex ID: W7237206985
FWCI:
Cites: 27
Cited by:
Related to: 10