Work

Impact of Automated Thermal Zoning on Building Energy Simulations: Ground-Truth Validation and Sensitivity Analysis

Year: 2026
Type: dissertation
Abstract: Urban building energy models lack information about dwelling layouts and stairwells, although thermal zoning influences energy, load, and comfort-related simulation results. This thesis evaluates the Multizone Assignment Algorithm for generating dwelling-stairwell thermal zoning for multi-family residential buildings from limited geometric and auxiliary input data. The methodology combines geometric and topological validation with a zoning variant sensitivity analysis. Two floor plan datasets are converted into a common ground-truth representation and compared with algorithm-generated zoning using validation metrics and diagnostic classifications. Zoning variants represent changes in zoning granularity, internal boundary placement, stairwell representation, and thermal treatment. Their effects on annual heating demand, peak heating load, and overheating hours are assessed in a TEASER-AixLib workflow under varying physical, operational, occupancy-related, and weather conditions. The results show that the algorithm reproduces the principal dwelling-stairwell structure. Less reliable outputs are associated with footprint geometry, inferred stairwell organisation, and estimated dwelling subdivision. The findings support its use as a scalable zoning approximation where floor plans are unavailable.
Language: English
Open Access status: green
OpenAlex ID: W7237318659
Cites: 42
Cited by:
Related to: 10