Comparative Assessment of Water Quality Parameters and Microbial Loads in Selected Well Water as an Index of Pollution: a Case Study of Ogbomoso, Oyo State, Nigeria
Year: 2026
Type: article
Abstract: Groundwater is regarded among others as the healthiest source of drinking water, but anthropogenic activities have led to its contamination in various parts of the world. This study investigated and compared water quality parameters and microbial loads in selected groundwater as an index of pollution in Ogbomoso, Oyo State. The physico-chemical parameters and the heavy metals were examined using standard laboratory procedures. Microbial loads of the water samples were quantified by membrane filteration method and media were prepared following the manufacturer’s instructions. Pollution index of water samples were determined by Arithmetic Index (WQI) and Nemerow’s pollution index. The result of physicochemical analysis showed temperature ranged from 25.00±0.00 – 29.00±0.00oC, Disolved Oxygen revealed higher concentration at station A (9.90±0.00 mg/L) in February while Biological Oxygen Demand showed values more than required limits across sampling stations. Electrical conductivity revealed highest value ranged from (1,166.00±7.21-5,500.00±173.21μs/cm) across the dry and wet months. highest turbidity values in December (A; 12.37±0.40, B; 10.33±0.58 and C 10.33±0.58 Ntu while range of 1.40±0.20-105.33±0.58 Ntu across stations in the wet seasons. Other Parameters were within the recommended limits of World Health Organization (WHO). However, heavy metal concentrations revealed Cu and Fe had high values in stations A to C in December, highest value was reported for Cu in A (5.47±0.29) in January. Pb revealed Below Detection Limits across the wet months except station A (0.40±0.00) in June, while its presence in some stations in the dry months were higher than the limits. Zn revealed highest values in December (4.57±0.25 mg/L) at station A, and January (78.40±58.20 mg/L) in station A. Microbial loads revealed highest coliform and viable counts in selected water sampled. Water quality indices indicated high pollution status of the groundwater sampled. The study concludes that majority of water samples examined were highly contaminated with large number of coliform and viable counts, high values of EC, turbidity, nutrient influx particularly phosphate concentration in some stations, heavy metal contamination in water samples collected near dumpsites and hospital were associated to influx of effluents from the sites. This study recommends serious water treatment before consumption and regular monitoring of the water sources.
Language: English
Subfield: Water Science and Technology
Field: Environmental Science
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W7237365337
FWCI:
Cites:
Cited by:
Related to:
