Work

Early postoperative objective residual astigmatism after femtosecond LASIK and toric implantable collamer lens implantation: a real-world overlap-weighted stratified comparison

Year: 2026
Type: article
Abstract: PURPOSE: To compare early postoperative automated-refraction-derived residual cylinder after femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and toric implantable collamer lens (TICL) implantation after balancing measured baseline refractive differences. METHODS: This retrospective real-world cohort used routine clinical records generated between October 2024 and March 2026. The primary endpoint was residual astigmatism greater than 0.50 D at M1, defined as the principal early postoperative analysis point rather than a strictly identical calendar-month visit across procedures. Propensity scores were estimated from age, sex, preoperative spherical equivalent, preoperative cylinder, axis type, and pupil diameter. Overlap weighting was the principal method; robust standard errors were clustered by patient. RESULTS: The final dataset contained 9,218 postoperative records from 3,114 patients and 5,192 eyes. The M1 analysis included 1,059 eyes from 665 patients. TICL eyes had greater baseline refractive burden than FS-LASIK eyes, including higher preoperative cylinder (1.67 vs 1.07 D). Crude analysis suggested higher odds of residual astigmatism after TICL (OR, 2.01; 95% CI, 1.37-2.94; P < 0.001). After overlap weighting, no statistically significant difference was observed in the marginal model (OR, 0.91; 95% CI, 0.57-1.46; P = 0.693) or the covariate-adjusted model (OR, 0.94; 95% CI, 0.59-1.51; P = 0.806). M1 interaction tests did not show statistically significant heterogeneity by cylinder severity or axis type. CONCLUSION: The crude excess of early objective residual astigmatism after TICL was substantially attenuated after balancing measured baseline refractive burden. Within the measured covariate-overlap population, no statistically significant procedure-related difference was observed at M1. These findings suggest that baseline refractive burden materially influenced the crude comparison and do not establish equivalence between procedures.
Language: English
Subfield: Ophthalmology
Field: Medicine
Open Access status: hybrid
Estimated APC paid: $3,790
OpenAlex ID: W7237710462
FWCI:
Cites: 37
Cited by:
Related to: 10