Comparative Evaluation of Light Microscopy, Rapid Diagnostic Tests and the Sysmex Xn-31 Analyzer for Malaria Diagnosis in a Hospital Setting in the Ashanti Region of Ghana
Year: 2026
Type: preprint
Abstract: Background Plasmodium falciparum accounts for approximately 98.1% of malaria infections in Ghana, and the Ashanti Region experiences year-round transmission. Because malaria symptoms overlap with other febrile illnesses, laboratory confirmation is essential before treatment. Light microscopy, rapid diagnostic tests (RDTs) and the Sysmex XN-31 automated hematology analyzer are all used for malaria diagnosis, but each has recognized limitations, and no study in Ghana has compared all three methods simultaneously on the same patient samples. This study evaluated the diagnostic performance of RDTs, light microscopy and the Sysmex XN-31 for malaria detection in a Ghanaian hospital setting. Methods This cross-sectional study recruited 234 patients with suspected malaria at Kwadaso SDA Hospital, Ashanti Region. Participants’ venous blood samples were simultaneously tested by light microscopy (reference standard), RDT, and the Sysmex XN-31. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and Cohen's kappa were calculated for each pairwise comparison. Spearman's correlation and Bland-Altman analysis assessed agreement in parasite density between the Sysmex XN-31 and microscopy, and Cochran's Q test assessed overall agreement among all three methods. Results Of 234 participants, 26 (11.1%) tested positive by both microscopy and the Sysmex XN-31, while the RDT detected 23 (9.8%). P. falciparum accounted for 23 (88.5%) of positive cases. Against microscopy, the RDT showed 88.5% sensitivity, 100% specificity, 100% PPV, 98.6% NPV and kappa = 0.932; identical figures were obtained against the Sysmex XN-31. Parasite density measurements from the Sysmex XN-31 correlated strongly with microscopy (rs = 0.948, p < 0.001), with Bland-Altman analysis showing a mean bias of − 1,063 parasites/µL. Cochran's Q test found no statistically significant difference in overall accuracy among the three methods (Q (2) = 6.000, p = 0.05). Conclusion Light microscopy, RDTs and the Sysmex XN-31 all showed reliable diagnostic performance for malaria detection, with almost perfect to perfect agreement across all pairwise comparisons. The RDT's narrower species coverage was the only meaningful point of difference among the three methods. These findings support the parallel deployment of all three methods across Ghana's tiered healthcare system, rather than treating any single method as a universal replacement.
Source: Research Square
Language: English
Topic: Malaria Research and Control
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7238725605