Effect of High‐Speed Railway Operational Conditions on the Dynamic AC Corrosion Behavior and Mechanisms of Pipeline Steel
Year: 2026
Type: article
Abstract: High‐speed railway operation induces dynamic AC interference on nearby buried steel pipelines, with periodic operating and shutdown periods. A dynamic AC corrosion simulation system incorporating AC current density, cathodic protection level, and shutdown period is established to investigate corrosion behavior and mechanism. The corrosion rate increases with increasing dynamic AC current density and first decreases and then increases with a negative shift in cathodic protection potential. Increasing the shutdown period from 0 to 6 h reduces corrosion rates under different cathodic protection conditions. Under a 5 h shutdown period, 300 A/m 2 AC interference, and −1.15 V SCE cathodic protection, the corrosion rate decreases from 1.047 mm/y after 19 h operation to 0.932 mm/y after 5 h shutdown and further stabilizes at approximately 0.52 mm/y after multiple operating–shutdown cycles. Shutdown‐period cathodic protection promotes corrosion product film stabilization and enhances corrosion resistance, revealing the mitigation mechanism of dynamic AC corrosion during high‐speed railway operational cycles.
Source: Materials and Corrosion
DOI: 10.1002/maco.70320
Authors: Shanshan Dong, Yanxia Du, Jiaze Sun, Le Chen
Institution: University of Science and Technology Beijing
Language: English
Subfield: Materials Chemistry
Field: Materials Science
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W7238732355