Work

Instrument Noise and Predictive Validation in Band-Resolved Indoor Wi-Fi Measurements: A Quality-Control Workflow for Spectrum-Analyser Surveys

Year: 2026
Type: article
Abstract: Spectrum-analyser Wi-Fi surveys often report band values near the noise floor and untested interpolated maps as exposure. We define a record-level quality-control workflow addressing both problems. Single-sweep 2–6 GHz spectra from 176 positions around nine ceiling-mounted access points were reanalysed. The workflow estimates a noise-equivalent field (EN) per record and band, applies a 2EN detection rule checked with a negative control and held-out pseudo-bands, audits range and overdrive status, and accepts a map only if it outperforms a leave-one-out mean. At 2.4 GHz, 56% of observations exceeded 2EN; in the 5 GHz intervals, 6–14% did, conditional on a noise model whose bias reached about 3 dB near 6 GHz; in the negative control, none of them did. Kriging, inverse-distance weighting and thin-plate splines generally did not outperform the mean, despite positive skill in a few cases; simulations show that a nugget-free continuous field would probably have been detected at a 2 m range, but at 1 m in only 46% of realizations, and rarely at shorter ranges or with a nugget or intermittent sampling. Screening quotients were at most 0.27% of the ICNIRP 2020 reference level; this is an indication, not a compliance assessment. Noise, range status and out-of-sample skill should be reported before interpretation.
Source: Sensors
Language: English
Open Access status: gold
Estimated APC paid: $3,137
OpenAlex ID: W7238740716
FWCI:
Cites:
Cited by:
Related to: