Work

Reflective Fiber-Tip Silica Microsphere Interferometer for Temperature Monitoring in Ethylene Glycol

Year: 2026
Type: article
Abstract: We experimentally investigate a reflective fiber-tip interferometric sensor comprising a fused-silica microsphere at the end of a single-mode fiber and an external mirror, both immersed in ethylene glycol. The sensor was interrogated with a broadband source, an optical circulator, and an optical spectrum analyzer. For the five retained heating spectra, the selected peak shifted from 1546.35 nm at 25.2 °C to 1548.53 nm at 65.2 °C. The fitted wavelength slope was 51.6 pm/°C (R2 = 0.9862). Ten consecutive spectral acquisitions at 40.5 °C showed a standard deviation of 0.163 nm in the tracked peak position. The positive shift is inconsistent with a fixed-gap response governed solely by the negative thermo-optic coefficient of ethylene glycol. The individual contributions to the shift were not isolated. These measurements establish the feasibility of the proposed single-ended architecture for temperature monitoring in ethylene glycol, while highlighting the need for improved thermal referencing, mechanical stabilization, and repeated heating–cooling cycles before quantitative metrological claims can be made.
Language: English
Open Access status: gold
Estimated APC paid: $1,448
OpenAlex ID: W7238748401
FWCI:
Cites: 30
Cited by:
Related to: