Work

Minutes to thermal shutdown of a walking robot: a documentation-based Modelica model of the twelve joint actuators of the Unitree Go2 — calibration, Kalman-filter winding sensor and preregistered blind tests on an open motor thermal data set

Year: 2026
Type: article
Abstract: Walking robots that carry a load are often stopped by hot joint actuators before their battery is empty. We build a physical model of the twelve joint actuators of the Unitree Go2 quadruped from public documentation and test it on the open Go2 motor thermal data set: 23 sessions, 48.2 h at a 2-s step, two robots, ten thermal shutdowns and two battery depletions. A data-driven model of the same robot already reproduces the motor temperature readings to about 1 °C. Our aim is different: to answer the questions an operator asks — how many minutes remain before the protection trips, which hidden node trips it, whether heat or the battery ends the mission first, how long a joint needs to cool down, and how a fleet must be planned in hot air. Documentation and calibration. The passport of the joint actuator was collected from the manufacturer’s web page, manual and robot description file, from independent teardowns and from an analogue motor. Without any fitting, the bus power balance closes at a joint-side torque constant of 0.82 N·m/A against 0.83 N·m/A from the documentation. The Modelica model has three thermal nodes per actuator, the leg structures and the body, the protection on the winding and the battery. It was calibrated with ADAO on two sessions of one robot; an analysis of these sessions showed from the drawing of the robot that the hip actuator does not exchange heat with the leg, and the revised model reduced the error on them from 3.1 to 1.7 °C. Results on 21 blind sessions of two robots. The tasks and metrics were registered (SHA-256) before any computation on the blind sessions. Motor temperatures: RMSE 2.20 °C with a bias of −0.04 °C; 2.16 °C on the second robot, never used in calibration; 2.27 °C with learned control policies, also absent from calibration. The model from documentation alone gives 8.7 °C. Kalman filter with a virtual winding sensor: forecast error 0.94, 1.25 and 1.93 °C 5, 10 and 30 min ahead, 2.4 to 1.3 times smaller than without the filter; warnings before 9 of 10 thermal shutdowns, 5 to 76 min in advance. Protection logic: tripping on the hidden winding node explains the shutdowns 23 % more accurately than the reading does, and in 7 of 10 events the model trips earlier, on the safe side. Heat or battery: the cause of every one of the 12 stops is named correctly; the energy per kilometre is 49.5 Wh/km against 47.3 Wh/km measured, about 9 km per charge. An FMU of the model agrees with OpenModelica within 0.005 °C and computes 48 h of operation in about a second. The model gives an operator the minutes of work under load, the share of time in work and the number of robots per post at 25 and 35 °C. For comparison, the data-driven model of the data-set authors, with 22 parameters fitted to this data set, reproduces the readings of the test sessions to about 1 °C. We name the data that would improve our result most: calibration sessions with learned policies and payloads, the manufacturer’s datasheet and winding channels.
Language: English
Open Access status: green
OpenAlex ID: W7238757835
FWCI:
Cites:
Cited by:
Related to: