External validation of the EK-LEF electrocardiogram model for left ventricular systolic dysfunction in three U.S. health systems

Year: 2026
Type: preprint
Abstract: Background: Heart failure is projected to affect more than 11 million U.S. adults by 2050, and reduced left ventricular ejection fraction (LVEF) can be present before symptoms appear. Deep learning models can detect reduced LVEF from the 12-lead electrocardiogram (ECG), but most have been tested only in the institutions that developed them, often after excluding patients with prior heart failure or recordings of poor quality. We evaluated EK-LEF, a self-supervised ECG model fine-tuned on low LVEF detection. Methods: A bidirectional Mamba encoder was pre-trained on 435,420 unlabeled MIMIC-IV ECGs and fine-tuned on 471,248 ECG–echocardiogram pairs from 235,969 patients at Mayo Clinic Rochester and the Mayo Clinic Health System. Mayo Clinic Florida served as the validation set and Mayo Clinic Arizona, a geographically distinct region, as the internal test set, each evaluated with one pair per patient. For external validation, Dandelion Health ran the model on one ECG from each of 17,500 patients at five hospitals in three U.S. health systems. The reference standard was LVEF ≤ 40% on transthoracic echocardiography within 15 days of the ECG. The primary outcomes were sensitivity and specificity. Results: In the Florida validation set of 14,880 patients, 9.9% of whom had LVEF ≤ 40%, the area under the receiver operating characteristic curve (AUROC) was 0.951 (95% CI 0.947–0.955). In the Arizona internal test set of 16,298 patients (prevalence 9.2%), it was 0.955 (0.950–0.959), with a sensitivity of 85.0% (83.1–86.8) and a specificity of 91.7% (91.3–92.2). The signal-quality rule excluded 2.2% of internal test recordings and 0.9% of external ECGs. Among the 17,344 external patients, of whom 9.4% had LVEF ≤ 40%, the model reached an AUROC of 0.912 (0.906–0.919), a sensitivity of 85.7% (84.1–87.4) and a specificity of 81.8% (81.3–82.4), and its negative predictive value was 98.2% (98.0–98.5). Sensitivity ranged from 79.5% to 90.2% between hospitals, and specificity was lowest in patients with a recorded cardiomyopathy (56.1%). Conclusions: EK-LEF retained high sensitivity and specificity at hospitals outside the health system in which it was developed. A negative result may help identify patients who do not need echocardiography.
Source: medRxiv
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W7238779699
Cites:
Cited by:
Related to: