Work

Fixed laboratory-axis readout of retained qubit information near a Floquet crossing

Year: 2026
Type: preprint
Abstract: Periodic driving can retain initial-state information, but its usefulness depends on the permitted readout. We study local estimation of an initial-state mixture coefficient in a driven spin–boson model. Each independently prepared copy is measured once at a uniformly sampled, recorded delay using one unchanged Pauli axis. Hierarchical equations of motion yield approximately twice the laboratory-x Fisher information at a Floquet-crossing reference as at two spectrum-selected controls. This readout accesses 90.81% of the mean quantum Fisher information and is nearly optimal within constant binary Pauli projections. The reference-to-control advantage persists throughout a 15° input cone within reconstructed numerical maps, but reverses for a known y input. A broader amplitude scan places the reference close to the largest sampled information. Together, these results give a reproducible, input-dependent benchmark that distinguishes information retained in the state from information accessible to a fixed laboratory readout.
Language: English
Open Access status: green
OpenAlex ID: W7238785335
Cites:
Cited by:
Related to: