Work

Dynamic Contrast-Enhanced Magnetic Resonance Imaging (DCE-MRI)-Guided Perfusion-Targeted Ultrasound-Stimulated Microbubble Enhancement of Radiation Response in a Xenograft Tumour Model

Year: 2026
Type: article
Abstract: Background: Ultrasound-stimulated microbubbles (USMB) have been demonstrated to enhance radiation-based tumour effects through synergistic action at the level of tumour vasculature. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a method that can be used for quantitative analysis of tissue vasculature. DCE-MRI parameters allow estimation of tissue perfusion and microvascular status. Methods: In the present study, DCE-MRI parameters were used to guide therapy modulation based on perfusion and were also used to monitor responses to treatment. New Zealand white rabbits bearing human-derived PC3 prostate cancer tumours were assigned to four different groups: untreated controls, animals treated with USMB (14 min; 750 kPa) alone, animals treated with 8 Gy dose of radiation therapy (XRT) alone, and animals treated with a combination of USMB+XRT. Animals receiving combined treatment were categorized in three groups: the first group received USMB+XRT, while the second and third groups received an additional 7 min pulse sequence in a particular area designated as lower perfusion (USMB+XRT, LOW) and high perfusion (USMB+XRT, HIGH), respectively. Treatment response was monitored using DCE-MRI, and changes in parameters were assessed before treatment (baseline) and at 24 h after treatment. Results: Results demonstrated that tumours treated with a combination of USMB and XRT exhibited a decrease in DCE-MRI-based measures of vascular characteristics (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05). Wash-in (s-1) DCE parameters demonstrated a decrease for combined treatment (USMB vs. USMB+XRT, HIGH, p < 0.05) (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05) in contrast to wash-out DCE parameters that indicated an increase for the combination group (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05). A decrease in area under the curve (AUC) was also observed for this group (USMB vs. USMB+XRT, HIGH, p < 0.05) (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05). Furthermore, a modified Toft’s model indicated an increase in the ve parameter (not statistically significant) and a decrease in the vp and kep parameters in the combined group (Control vs. USMB+XRT, HIGH, p < 0.05) (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05) and (USMB+XRT vs. USMB+XRT, HIGH, p < 0.05), respectively. Correlative histology was obtained and analyzed, indicating cellular destruction of the vasculature which was associated with imaging-based levels of response. Results from tumours that underwent further perfusion-targeted treatment (based on increased or decreased perfusion) indicated enhanced vascular responses (in hypo- or hypervascularized areas). Conclusion: DCE-MRI shows promise in monitoring treatment response.
Source: Cancers
Language: English
Open Access status: gold
Estimated APC paid: $3,499
OpenAlex ID: W7238807430
FWCI:
Cites:
Cited by:
Related to: