Flexural Behavior of RC Slabs Strengthened with a Reinforced Concrete Overlay
Year: 2026
Type: article
Abstract: Increasing the cross-section with concrete is a common method of strengthening reinforced concrete slabs, the effectiveness of which is determined by the conditions of composite action between the layers. Single-span RC slabs strengthened with a cast-in-place reinforced concrete overlay were tested in flexure to evaluate the influence of the interface connection type on their structural response. Two interface configurations were investigated: a substrate without intentional surface preparation or shear connectors (NIC) and a mechanically connected interface with Ø8 mm shear keys at 400 × 200 mm spacing (WIC). The tests were carried out in bending up to failure, and strains were recorded using the digital image correlation method. The load-bearing capacity of the strengthened slabs, defined by the moment at the ultimate concrete strain Mcu, exceeded that of the control slab (CS) by 143.5% for NIC and 146.1% for WIC, whereas the maximum experimental moment Mmax exceeded that of CS by 137.3% and 203.7%, respectively, and the maximum moment of the WIC slabs was 28% higher than that of NIC (17.28 kN·m versus 13.50 kN·m). A comparative analysis was performed with calculated curves based on the deformation model in accordance with DBN V.2.6-98:2009. For the strengthened slabs, the model satisfactorily predicts the moment at which the DIC surface strain at the level of the lower reinforcement reaches the nominal yield threshold (deviation up to 5%) and the bending moment at which the ultimate concrete strain is reached (deviation up to 9.1%), but does not capture the post-limit reserve of the strengthened sections: after the ultimate concrete strain was reached, the slabs continued to carry load up to 13.50 kN·m (NIC) and 17.28 kN·m (WIC), i.e., 9.8% and 40.6% above the theoretical ultimate moment. The maximum experimental deflection of WIC is close to the theoretical ultimate deflection (+1.52%), whereas that of NIC exceeds it by 44.5%, which may be associated with interlayer slip. Since these deflections correspond to different bending moments, they characterize the ultimate deformability rather than the accuracy of the model. In the analytical model, the ultimate concrete compressive strain is attained while the strain at the level of the overlay top reinforcement remains below the yield threshold; in the tests, however, the DIC surface strains measured at this level attained the nominal yield threshold in both series, and a substantial post-limit reserve developed in the sections.
Source: Applied Sciences
DOI: 10.3390/app162311600
Authors: Mykhailo Ivaneiko(Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Visualization, Writing – original draft), Andrii Klym(Investigation, Methodology, Validation, Writing – review & editing), Yaroslav Blikharskyy(Conceptualization, Supervision, Validation, Writing – review & editing), Jacek Selejdak(Methodology, Supervision, Visualization, Writing – review & editing), Roman Khmil(Data curation, Formal analysis, Validation, Writing – original draft), Zinoviy Blikharskyy(Conceptualization, Formal analysis, Supervision, Writing – original draft)
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,896
OpenAlex ID: W7238831040
