Work

Robotic right hemicolectomy with CME: Surgical platform strategies for the new Hugo™ RAS System

Year: 2026
Type: preprint
Abstract: Introduction The introduction of novel robotic platforms requires adaptation of established surgical workflows and dedicated training. The Hugo™ Robotic-Assisted Surgery (RAS) System features independently positioned arm carts, providing flexibility but requiring precise setup and docking strategies. This study aimed to establish a standardized setup for robotic right hemicolectomy with complete mesocolic excision (CME) using the “critical view” technique and to evaluate associated learning curves. Methods A prospective, single-center simulation study was conducted at the Center for Medical Innovation and Technology (CeMIT), University Hospital Cologne, between April and October 2025. A three-dimensional printed anatomical model based on an anonymized patient CT scan was used. A standardized trocar and cart configuration was developed through iterative testing. Six surgical residents and five experienced robotic surgeons performed four standardized operative views, docking, and emergency de-docking, with five repetitions per participant. Procedure times were analyzed using linear mixed-effects models. Results An optimized “critical view” setup was established, consisting of a diagonal trocar configuration with individually defined tilt and angulation parameters. Experienced surgeons performed operative steps significantly faster than residents (p = 0.018). Both groups demonstrated significant improvement with repeated procedures (p < 0.001), with comparable learning effects (p = 0.489). Procedure times decreased by 30% among residents and 24% among experienced surgeons between the first and second repetition. Docking was significantly faster in experienced surgeons (p = 0.002), whereas improvement over repetitions was more pronounced among residents (p = 0.016). Emergency de-docking also demonstrated significant learning effects in both groups (p < 0.001). Discussion A standardized “critical view” setup for right hemicolectomy using the Hugo™ RAS System is feasible in simulation. Repeated training significantly improved performance in both experienced surgeons and residents. These findings support structured simulation-based training, including operative steps, docking, and emergency de-docking. Clinical validation is warranted.
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: green
OpenAlex ID: W7238867707
Cites: 32
Cited by:
Related to: