Work

Ease of Endotracheal Intubation and Hemodynamic Changes Following Topical Airway Anaesthesia Spray in Critically Ill Patients: An Observational Study

Year: 2026
Type: article
Abstract: Background and Aims: Endotracheal intubation in critically ill patients was frequently associated with hemodynamic instability and procedure-related complications. Although rapid sequence intubation (RSI) remains the standard approach, it may be relatively contraindicated or high-risk in patients with severe hemodynamic compromise or anticipated periintubation instability. In such scenarios, adjunctive techniques that attenuate airway reflexes without significant systemic effects may improve intubation conditions. Topical airway anaesthesia with lignocaine spray offers a potential strategy to facilitate airway management while minimising physiological derangements. This study aimed to assess the use of 10% lignocaine spray in facilitating intubation and its impact on hemodynamic parameters in critically ill patients. Materials and Methods: This hospital-based cross-sectional study was conducted in the Emergency Department of a tertiary care centre. It included 100 adult patients with Glasgow Coma Scale (GCS) ≤8 with clinical indications for airway protection requiring endotracheal intubation. Topical airway anaesthesia was administered using 10% lignocaine spray as an adjunct to standard airway management protocols before laryngoscopy. Ease of intubation was assessed using Modified Cormack–Lehane grading and first-pass success rate. Hemodynamic parameters, including heart rate, mean arterial pressure (MAP), and oxygen saturation (SpO₂), were recorded at baseline and at 2, 5, 10, and 15 minutes post-intubation. Statistical analysis was performed using the chi-square test, Fisher’s exact test, and repeated-measures ANOVA. Results: The first-pass success rate was 83% (95% confidence interval: 76%–90%). Favourable laryngoscopic views (Grade I–IIa) were observed in 67% of patients and were significantly associated with first-pass success (p < 0.001). Heart rate increased transiently immediately after intubation, while mean arterial pressure initially decreased and subsequently stabilised. Oxygen saturation improved progressively over time. All hemodynamic changes were statistically significant (p < 0.001). Complications occurred in a small proportion of patients. Conclusion: Topical airway anaesthesia using 10% lignocaine spray appears to be a clinically feasible adjunct, with favourable intubation conditions and acceptable hemodynamic parameters observed in critically ill patients. It may serve as a useful adjunct in emergency airway management, particularly in patients for whom standard RSI may be high risk or relatively contraindicated.
Language: English
Field: Medicine
Open Access status: bronze
OpenAlex ID: W7238868528
FWCI:
Cites: 12
Cited by:
Related to: