Temperature Prediction and Fatigue Assessment of District Heating Pipelines Using a DNN–LSTM Hybrid Model

Year: 2026
Type: article
Abstract: This study compared DNN–LSTM, RF, and XGBoost temperature prediction using six heating season records and then optimized the selected DNN–LSTM model with PSO. At forecast origin t, 24 h of available inputs were used to predict temperature at t + 60 min. The primary supply test R2 was 0.9909 and MAPE was 0.79%. For fatigue assessment, the available six-year measured and predicted primar -network temperature series were cleaned and separately subjected to sequential rainflow counting. The six-year values were scaled by a factor of five to obtain 30-year equivalent values. Under a nominal fully restrained thermal stress model and a base metal S–N parameter, predicted 30-year damage was 6.066 × 10−7 versus 1.698 × 10−6 from measured supply temperature and 1.363 × 10−7 versus 2.563 × 10−7 from measured return temperature, corresponding to differences of −64.28% and −46.80%. These conditional calculations show that pointwise temperature accuracy and total cycle agreement do not establish fatigue damage agreement; local weld damage and remaining life require further validation.
Source: Buildings
Language: English
Open Access status: gold
Estimated APC paid: $3,137
OpenAlex ID: W7238869569
FWCI:
Cites: 27
Cited by: