Association between EASIX and all-cause mortality in patients with ventilator-associated pneumonia: a retrospective cohort study from the MIMIC-IV database
Year: 2026
Type: preprint
Abstract: Background Ventilator-associated pneumonia (VAP) is a common ICU-acquired infection with high mortality. The Endothelial Activation and Stress Index (EASIX), a marker of endothelial dysfunction, has shown prognostic value in various critical illnesses, including respiratory diseases such as ARDS and COPD. However, its association with all-cause mortality in patients with VAP remains unclear. This study aimed to evaluate the prognostic value of EASIX in VAP patients using the MIMIC-IV database. Methods Data were retrieved from the Medical Information Mart for Intensive Care IV (MIMIC-IV) version 3.1 database. Adult patients diagnosed with VAP and an ICU stay of more than 24 hours were eligible. EASIX was calculated using the standard formula and log2-transformed before analysis. Subjects were stratified by tertiles of log2-EASIX. The primary endpoint was 28-day all-cause mortality, and the secondary endpoint was 90-day all-cause mortality. The Boruta algorithm was used for covariate selection. Multivariable Cox proportional hazards regression, Kaplan–Meier survival curves, and restricted cubic spline (RCS) analyses were performed to assess the relationship between EASIX and prognosis. Results The analytic cohort comprised 1673 patients with VAP, including 343 (20.5%) non-survivors and 1330 (79.5%) survivors. Non-survivors exhibited significantly higher log2-EASIX levels than survivors (median [IQR]: 1.74 [0.77–2.99] vs. 1.12 [0.15–2.25]; P < 0.001). In the fully adjusted Cox model, each 1-unit increase in log2-EASIX was independently associated with higher 28-day and 90-day mortality (P < 0.001). Relative to the lowest tertile, the highest tertile of log2-EASIX was associated with a greater risk of 28-day mortality (HR 1.68, 95% CI 1.15–2.46; P = 0.008) and 90-day mortality (HR 2.11, 95% CI 1.54–2.88; P < 0.001). Kaplan–Meier analysis demonstrated that patients with higher EASIX tertiles had significantly lower survival. RCS modelling indicated a near-linear relationship. Stratified analyses indicated that the association remained robust across subgroups. Conclusions Elevated EASIX levels were independently associated with an increased risk of 28-day and 90-day all-cause mortality in critically ill patients with VAP. EASIX may serve as a simple, readily available, and useful prognostic marker for risk stratification in this population. Further prospective studies are warranted to validate its clinical utility.
Source: Research Square
Authors: Linlin Lv, Weiqi Li, Gang Li, Fangyi Li
Institutions: Sun Yat-sen University, Sun Yat-sen Memorial Hospital
Language: English
Topic: Nosocomial Infections in ICU
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7238876898
