Work

Inverse Finite-Element Identification of Hydraulically Stabilised Layers from Static Plate Load Tests on a Full-Scale Circular Test Track, with Geopolymer-Stabilised Alternatives

Year: 2026
Type: preprint
Abstract: Static plate load tests are routinely used to accept treated pavement layers, but the strain moduli Ev1 and Ev2 describe the layered system, not the layer. This study identifies the elasto-plastic parameters of the subgrade and of three hydraulically treated layers built on a full-scale circular test track (ALT-LIRA, Iaşi, Romania): a soil stabilised in place, a treated sandy gravel and a treated milled cement concrete. The complete first-loading–unloading–reloading plate curves were back-analysed with an axisymmetric finite-element model in Ansys Mechanical APDL, verified against independent layered-elastic and finite-element solutions (differences ≤0.1 %). The tested layers were described with an extended Drucker–Prager model with isotropic hardening, and the parameters were identified by Latin hypercube sampling followed by Levenberg–Marquardt optimisation, together with their uncertainty. For the subgrade, the model reproduced Ev1 and Ev2 within 3 % and 9 % (E=41 MPa, coefficient of variation 13 %). For the stabilised subgrade, the curve was reproduced within the resolution of the dial gauge, but the modulus of the treated layer and the stiffness of its support were almost perfectly correlated (r=−0.99): the test identifies the stiffness of the layered system, and the support had to be 4.5–4.7 times stiffer than indicated by tests on the untreated soil. The test on the treated milled concrete was at the resolution limit of the gauge, and the test on the treated sandy gravel, dominated by volumetric compaction under the plate, could not be described by the shear-hardening model. Light-weight deflectometer moduli computed with the identified parameters agreed with the measured ones within 30 % on the subgrade, but on the treated layers the measured moduli saturated at 93–177 MPa, well below the static stiffness, so that the deflectometer could not discriminate between stiff treated layers. Scenarios with geopolymer-treated layers, with strengths taken from the literature and a modulus–strength scaling calibrated on the built layers, indicate that the same plate response could be obtained with 154–171 mm of geopolymer-stabilised soil and with 115–139 mm of geopolymer-treated recycled concrete instead of 200 mm. The results show that the strain moduli of treated layers should be interpreted as system indices, and they provide a mechanical basis for comparing alternative, lower-carbon binders with the reference layers.
Language: English
Open Access status: green
OpenAlex ID: W7239367689
Cites:
Cited by:
Related to: 10