Work

A new diagnostic pipeline for recurrent diffuse podocytopathies post transplantation using glomerulus-on-a-chip technology

Year: 2026
Type: preprint
Abstract: Introduction: Recurrent diffuse podocytopathies in kidney transplants are a leading cause of graft loss with poorly understood pathophysiology and variable response to therapy. Recent work has focussed on anti-slit diaphragm antibodies, but reliable methodology for their detection has proven challenging. In addition, antibody-associated disease only accounts for disease mechanism in a proportion of patients. Clinicians need a reliable stratification pathway, firstly, to determine if a circulating factor indiscriminate of its nature is present, and secondly, to establish whether it is antibody-associated or otherwise, to facilitate a precision medicine approach to therapeutic management and transplantation. Methods: This exploratory cohort study used primary glomerular cells within a modified Glomerulus-On-A-Chip (GOAC) model. To identify the presence of a pathogenic circulating factor, we exposed the GOAC to an inception cohort of healthy control (n=4), non-recurrent (n=4) and recurrent disease sera (n=14); assessing permeability by the addition of fluorescein isothiocyanate conjugate (FITC) albumin. To determine if recurrent disease was antibody-associated or otherwise, immunostaining was performed on sera-exposed GOACs and post-recurrence allograft biopsies. Subsequently, we validated our pipeline on six sera blinded to clinical outcome. Results: GOAC exposure with all recurrent disease sera resulted in an increase in albumin permeability compared with healthy controls. The mean fold difference between recurrent and non-recurrent disease sera permeability was 3.42 (p <0.001). An anti-nephrin antibody-associated pattern was found by immunostaining for 9/13 (69%) recurrent disease sera and was consistent with individual clinical response to antibody-targeted therapy. ROC curve analysis showed excellent sensitivity and specificity of our pipeline (AUC 0.977, p <0.0001) which accurately predicted clinical outcomes for all six patients in the blinded validation cohort. Conclusions: This functional GOAC pipeline accurately determines the presence of a pathogenic circulating factor and can define it as anti-nephrin-associated or otherwise to guide therapeutic strategy and optimise approaches to transplantation.
Source: medRxiv
Language: English
Subfield: Nephrology
Field: Medicine
Open Access status: green
OpenAlex ID: W7240257232
Cites:
Cited by:
Related to: