Work

Study of MWPCs with interpolating pad readout for high multiplicity charged particle detection

Year: 1990
Type: conference-paper
Abstract: Two types of MWPC with interpolating cathode pad'' readout for two dimensional position sensitive detection have been studied. One type uses rectangular pads and resistive charge division. A detector with an active area of 26 cm {times} 16 cm, over 1000 readout channels has been built. With readout spacing of 1 cm, a position resolution of {approximately}70{mu}m (rms) for 5.4 keV x-rays and a differential non-linearity of {plus minus}6% have been achieved. Another type of detector uses chevron'' shaped pads for geometrical charge division. Position resolution {approximately}50{mu}m (rms) for 5.4 keV x-rays has been observed in a test detector and results of an investigation to reduce differential non-linearity are reported. 11 refs., 6 figs.
Authors: Debbe, R., Fischer, J., Lissauer, D., Ludlam, T. W., Makowiecki, D., O'Brien, E., Radeka, V., Rescia, S., Rogers, L. C., Smith, G. C., Stephani, D., Yu, B. (Brookhaven National Lab., Upton, NY (USA)), Greene, S. V., Hemmick, T. K., Mitchell, J. T., Shivakumar, B. (Yale Univ., New Haven, CT (USA)), Mathieson, E. (Leicester Univ. (UK))
Language: English
Open Access status: green
OpenAlex ID: W72538555
FWCI:
Cites: 8
Cited by:
Related to: 10