Work

Dynamic damage identification using linear and nonlinear testing methods on a two-span prestressed concrete bridge

Year: 2012
Type: conference-paper
Abstract: In this paper dynamic testing methods on a two span prestressed concrete bridge are examined to evaluate the ability on damage assessment on civil engineering structures in situ. The testing methods are based on analysing modal parameters, i.e. the eigenfrequencies and the modeshapes, as well as the calculation of the corresponding flexibility matrix. Variations on them are shown for different damage states, realised by continuously cutting tendons and loading the bridge with an experimental mass of 245t. Moreover, the evaluation of nonlinear parameters as the amplitude dependency of the eigenfrequencies is also presented. For the different damage states cracks are noticed at the different cutting sections. As nonlinear parameter and the modeshapes do not retrieve clear indications on the damage, the changes of the eigenfrequencies and the flexibility matrices demonstrate, in contrast, clearly the capability on damage assessment on the investigated object. Figure 1. Picture of the bridge in winter 2010. Figure 2. Longitudinal Section of the bridge with the cutting sections and the position of the experimental mass. Figure 3. Schematic cross section of the bridge with all the tendons. Figure 4. Longitudinal section of the bridge showing only the tendons. 2 TESTING PROCEDURES 2.1 Damage scenarios In order to validate the presented testing methods for damage assessment, tests are conducted for different damage scenarios. Table 1 summarises the different damage states (intact #0 to the most damaged #4) by continuously cutting a defined number of tendons at two different sections of the bridge, as illustrated on Figure 2. Figures 5a-5d illustrates schematically the different damage scenarios for the selected sections. These damage states are crucial to evaluate the sensitivity of the test results according the severity of introduced damage and formation of cracks. This is achieved by firstly cutting a defined number of tendons and secondly by loading the bridge with an additional experimental mass of 245 t, consisting of 38 beam blanks from ArcelorMittal (Fig. 6). One has to add, that for each damage state, except for #4, the bridge is loaded with the experimental mass for static and additional dynamic measurements (data not shown). Table 1. Description of the damage scenarios according to the cutting sections shown on Figure 2. Damage state Cutting tendons Percentage cutting (100% equals all tendons in the defined section) x=29.25 m x=63.5 m # 0 Undamaged state 0% 0% # 1 20 straight lined tendons in the lower part of the bridge (x=29.25 m), (Fig. 5a) 33.7% 0% # 2 8 straight lined tendons in the upper part of the bridge over the pylon (x=63.5 m), (Fig. 5b) 33.7% 12.6% # 3 56 external tendons, (Fig. 5c) 46.1% 24.2% # 4 16 straight lined and 8 parabolic tendons in the upper part of the bridge (x=63.5 m), (Fig. 5d) 46.1% 62.12% Figure 5a. Damage state #1 for the cutting line at x=29.25 m. Figure 5b. Damage state #2 for the cutting line at x=63.5 m. Figure 5c. Damage state #3 for the cutting line at x=63.5 m. Figure 5d. Damage state #4 for the cutting line at x=63.5 m. Figure 6. Experimental mass, after loading with 31 of 38 beam blanks.
Language: English
Open Access status: green
OpenAlex ID: W770288408
FWCI: 1.902
Cites: 5
Cited by: 2
Related to: 10