Work

The Development of Anomaly Diagnosis Method Using Neuro-Expert for PWR Monitoring System

Year: 2006
Type: article
Abstract: DEVELOPMENT OF ANOMALY DIAGNOSIS METHOD USING NEURO EXPERT FOR PWR MONITORING SYSTEM. The monitoring system for a huge and complex Pressurized Water Reactor (PWR) has some difficulties of monitoring task due to the dynamic system with large number of plant signals. The anomaly detection using neural networks integrated in the monitoring system improves the reactor safety to detect the anomaly faster than conventional methods. Previously, the research developed a PWR monitoring system connected online with data acquisition system. The combination of neural network and expert system (neuro-expert) is utilized to improve the time-process in anomaly detection. The advanced research considered the online anomaly diagnosis using expert system to complete the monitoring system tasks. Furthermore, reliable method of combination method, neuro-expert has been developed and tested in some anomaly conditions using PWR simulator. Maximum error of initial learning is 1.866 % and the fault level was involved for critical value determination of anomaly condition. The expert system diagnose the early alert from neural network to determine the cause. In simulation, the neuro-expert system could detect the anomaly faster than the conventional alarm system.
Language: English
Open Access status: green
OpenAlex ID: W80002100
FWCI: 1.778
Cites: 3
Cited by: 6
Related to: 10