Year: 1986
Type: article
Abstract: Run SB-CL-05 is a 5% break in the side of the cold leg. The test results show that the core was uncovered briefly and that the rods overheated at certain core locations. Liquid holdup on the upflow side of the steam generator tubes was observed. When the loop seal cleared, the core refilled and the rods cooled. The TRAC results are in reasonable agreement with the test data, meaning that TRAC correctly predicted the major trends and phenomena. TRAC predicted the core uncovery, the resulting rod heatup, and the liquid holdup on the upflow side of the steam generator tubes correctly. The clearing of the loop seal allowed core recovery and cooled the overheated rods just as it had in the data, but TRAC predicted its occurrence 20 s late. The experimental and TRAC analysis results of run SB-CL-05 are similar to those for Semiscale Run S-UT-8. In both runs there was core uncovery, rod overheating, and steam generator liquid holdup. These results confirm scaling of these phenomena from Semiscale (1/1650) to LSTF (1/48).
Authors: F.E. Motley, Ryan Schultz
Language: English
Subfield: Nuclear Energy and Engineering
Field: Energy
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W80268946