Work

Summary of International Data on Monitored Low-energy Houses: a Compilation and Economic Analysis

Year: 1983
Type: article
Abstract: In the Building Energy-Use Compilation and Analysis (BECA) project, Part A (New homes), we have analyzed 215 submetered, energy-efficient residential buildings (including 7 small multi-family buildings comprising 68 single-family units).We compare the energy use of these buildings, normalized to an indoor temperatu~e of 20 o C. The average thermal integrity of these buildings is 53 kJ/m DDC.These compare favorably to U.S. 1979 building practice of 100 kJ/m2DDC and U.S. Stock at 180 kJ/m 2 DDC.We have data on the added first cost of conservation measures for 202 buildings.Of these buildings, the only homes that have costs of conserved energy below current energy costs are those with superinsulation, either alone or combined with low-aperture, passive-solar design.We continue to collect data and solicit the reader's participation.
Language: English
Open Access status: green
OpenAlex ID: W813790
FWCI: 3.862
Cites: 3
Cited by: 1
Related to: 10