Year: 2006
Type: dissertation
Abstract: This thesis presents a reliability evaluation of stacked die ball grid array (BGA) assemblies under mechanical bending loads. The test specimens used in this investigation were four die stacked BGAs assembled on printed circuit boards (PCBs) with eutectic tin-lead solder and gold over nickel finishes, both as-reflowed and after aging. The failure envelopes of both types of specimen were quantified in terms of PCB flexural strain and strain rate. The experimental data from cyclic bending tests at three strain amplitudes with a constant strain rate have been used to determine the effect of strain amplitudes on cycles to failure. The experimental data from cyclic bending tests were combined with the data from impact tests to determine the effect of strain rate to cycles to failure. The failure sites associated with each test condition were identified, and failure site transition phenomena are reported and discussed.
Author: Bo Song
Institution: University of Maryland, College Park
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W83252811