Trade-Off between Cool Roofs and Attic Insulation in New Single-Family Residential Buildings
Year: 1998
Type: article
Abstract: This paper s~mmarizes a comparative analysis of the impact of roof surface solar absorptance and attic insulation on simulated residential annual cooling and heating energy use in sixteen sunbelt climates. The buildings are single-story, single-family, new construction residences with either a gas furnace or an electric heat pump and with ducts in the attic or conditioned zone. Annual energy use is simulated with DOE-2 for dark and cool roofs and eleven attic insulation R-values ranging from 1 through 60. The simulations are regressed as a function of roof system conductance and roof absorptance for each heating system, duct location I insulation level, and climate. An equivalent change in conductance is calculated for a given change in absorptance from a dark to a cool roof. Equivalent attic insulation R-values are found from the conductance of the cool roof. Reductions in .R-value are observed in all buildings and climates. The analysis demonstrates that a roof system with a cool roof and low attic insulation can be used as an alternative to the more conven~ tional dark-colored roof with a high level of insulation, with a zero net change in the annual energy bill. Similar work was previously done in support of revisions to ASHRAE commercial building standard 90.1.
Authors: S. Konopacki, Hashem Akbari
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: green
Awards: G1614572836, G1643223109, G193590374
OpenAlex ID: W84197267