Measurement methodology for the alignment accuracy of wafer stepper
Year: 1994
Type: article
Abstract: To meet the process requirement of semiconductor device manufacturing, it is necessary to improve the alignment accuracy in exposure equipments. We developed the excimer laser stepper and will describe the methodology for alignment measurement and experimental results. Our wafer alignment system consists of off-axis optics, TTL(Through The Lens) optics and high precision stage. Off-axis alignment utilizes the image processing and /or diffraction from thealign marks of off-centered chip area. On the other hand, TTL alignment can be used for the die-by-die alignment using dual beam interferometry. When only off-axis alignment was used, the experimental alignment error(lml+3 .sigma. ) was 0.26-0.29 .mu. m, and will be reduced down to 0.15 .mu. m by adding TTL alignment.
Authors: J.H. Lee, Wonwoo Jang, D.H. Kim, Byong-Sub Nam, J.H. Kim
Language: Korean
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W856516198