Work

Thermal barrier confinement experiments in TMX-U tandem mirror, revision 1

Year: 1984
Type: article
Abstract: In our recent experiments on the TMX-U thermal-barrier device, we achieved the end plugging of axial ion losses up to a central cell density of n/sub c/ = 6 x 10/sup 12/ cm/sup -3/. During lower density experiments, we measured the axial potential profile characteristic of a thermal barrier and found an ion-confining potential greater than 1.5 kV and a potential depression of 0.45 kV in the barrier region. The average beta of hot end plug electrons has reached 15% and of hot central cell ions has reached 6%. In addition, we heated deuterium ions in the central cell with ICRF to an average perpendicular energy of 2 keV. During strong end plugging at low density (7 x 10/sup 11/ cm/sup -3/), the axial ion confinement time tau/sub parallel to/ reached 50 to 100 ms while the nonambiopolar radial ion confinement time tau/sub perpendicular to/ was 14 ms - independent of end plugging. Electrically floating end walls doubled the radial ion confinement time. At higher densities and lower potentials, tau/sub parallel to/ was 6 to 12 ms and tau/sub perpendicular to/ exceeded 100 ms.
Language: English
Open Access status: green
OpenAlex ID: W87393063
FWCI:
Cites: 9
Cited by:
Related to: 10