Laringoskopija visoke rezolucije u dijagnozi poremećaja glasnica
Year: 2012
Type: article
Study design: Case Report
Abstract: Aim: Our aim is to underline the superiority of Wolf endocam among other high resolution close-up laryngoscopy devices.We use a camera made by Richard Wolf GmbH (Knittlingen, Germany).High-Speed Endocam 5562 was constructed specifically for laryngoscopy, so it is equipped with an automatic focus.Case report: Patient whom we present is a 58-years old female who displayed throat discomfort and harsh voice for nearly a month.Her medical history was unremarkable except for the cervical spine tenderness.When examined with High-Speed Endocam 5562, vocal fold hematoma became visible.Discussion: So far, we have found various anatomical variations with or without epithelial damage.High resolution laryngoscopy shows a better and more objective view of vocal fold defects with no room for speculation based on subjective observation of obvious defects.With the use of Wolf endocamera precise positions are determined and accurate treatment can be achieved, also choosing a suitable approach.When surgical treatment is indicated, this imagining improves preoperative understanding of the problem, subsequently increasing the odds of success.Conclusion: Once handled by an experienced physician, up to 20 patients can be examined each day.Examination is performed quickly and without the need for local anesthesia.Endocamera offers reliability and objectivity as findings may be recorded and reviewed when necessary.This enables treating the patients adequately as making a fully informed decision is significantly upgraded by superior visual documentation of local condition. Key words: endoscopic camera, high resolution close-up laryngoscopy, vocal foldsSažetak.Cilj: Cilj nam je istaknuti superiornost Wolfove endokamere nad ostalim uređajima za izravnu laringoskopiju visoke rezolucije.Kamera koju koristimo, High-Speed Endocam 5562®, izgrađena je posebno za laringoskopiju, te je opremljena automatskim fokusom, a proizvodi je Richard Wolf GmbH (Knittlingen, Njemačka).Prikaz slučaja: Prikazujemo 58-godišnju bolesnicu koja se žali na teškoće s grlom i hrapav glas kroz gotovo mjesec dana.Povijest bolesti ne pokazuje osobitosti, osim palpatorne bolne osjetljivosti vratne kralježnice.Pregledom kamerom High-Speed Endocam 5562 jasno smo uočili vokalni hematom.Rasprava: Tijekom svakodnevnih pregleda nalazimo razne anatomske varijacije, neke uz oštećenje, a neke bez oštećenja epitela.Laringoskopija visoke rezolucije omogućuje bolji pregled defekata vokalnih nabora, ne ostavljajući prostor za spekulacije i subjektivnost.Korištenjem Wolfove endokamere određuje se i precizna pozicija lezije, te je lakše odrediti adekvatnu terapiju.Kod indiciranog kirurškog zahvata ovakva vizualizacija poboljšava predoperativno razumijevanje problema, a time i izglede za uspjeh.Zaključak: Ako je kamera u rukama iskusnih liječnika, moguće je obraditi do 20 bolesnika dnevno.Pregled se obavlja brzo i bez potrebe za lokalnom anestezijom.Endokamera nudi pouzdanost i objektivnost, a rezultati se mogu snimiti i pregledati kada je to potrebno.To omogućuje adekvatno liječenje bolesnika i stvaranje potpuno informirane odluke zasnovane na vrhunskoj vizualnoj dokumentaciji lokalnog stanja.
Institutions: Klinički Bolnički Centar Rijeka, University of Rijeka
Language: Croatian
Topic: Voice and Speech Disorders
Subfield: Speech and Hearing
Field: Health Professions
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W89412483
