On freezing resistance of borehole heat exchangers
Year: 2015
Type: conference-paper
Abstract: Introduction The ground source heat pump (GSHP) systems used to provide heating and cooling of buildings are installed in the ground with high density polyethylene (HDPE) pipes and the surrounding empty space is filled with the grout material in the borehole. It refers to closed loop borehole heat exchangers (BHE). Through the installed HDPE pipes, a pump that circulates anti-freeze mixture exchanges heat along the buried BHE with the ground. During the operations, the backfilling materials of BHE, particularly the grout material, must ensure an efficient thermal contact and durability. Particularly for heating purposes, BHEs can be operated below the freezing point of water. Consequently, backfilling materials contract due to cooling and the freezing water inside the pores of the grout generates expansion and growing of icelenses. These thermo-mechanical behaviors may damage the grout and decrease the performance of BHE. About the thermal stress investigation of GSHP systems, several investigations have been reported about the impact of heating and cooling processes of axial stress and strain of energy piles [1-2]. However, those studies refer to axial thermal stresses and the freezing effect is clearly disregarded. Considering the growing ice lenses in the pores of grout material, some theoretical models are described in the literature provides significant information about the behavior of freezing in a porous medium [3-5]. According to these studies, the expansion of water freezing may have a significant impact on the stress state for elevate water saturation ratio (>90%). Suction draws water at the interface between ice-lens and liquid water brings the liquid towards the freezing front. In addition, the freezing pressure correlates to the permeability. The high permeability allows the liquid to flow easily through the pore throats to decrease the pressure. In contrast, low permeability increases the pressure in the pores, and the thin water film between the ice formation and the grains acting as the disjoining force that opens new flow paths which damage the medium. Concerning, the experimental works about the freezing of porous materials in the literature, most of the studies address the resistance of concrete mortar or Portland-cement paste to the freeze-thaw cycles caused by surface temperature conditions [6-9]. The applied boundary conditions play important role on the crack development. Concerning backfilling materials for BHE, there exist a very limited number of investigations but they do not consider realistic thermal boundary conditions of a BHE [10-11]. A recent tentative of experimental study of freezing effect on co-axial BHE has been carried out by [12]. They demonstrate a significant loss of integrity of the geothermal probe but it is to mention that the freezing effect was probably too severe. The objective of the present study is to understand the behavior of thermo-mechanical behavior of porous grout material used for GSHP systems and in particular how the freezing process causes degradation on a grouted BHE. The study is carried out with some laboratory experiments and theoretical approaches.
Authors: Selçuk Erol, Bertrand François
Institution: Université Libre de Bruxelles
Language: English
Field: Energy
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W894476273