Work

A state variable approach to the BESSY II local beam-position-feedback system

Year: 1996
Type: conference-paper
Abstract: At the BESSY II facility, stability of the electron beam position and angle near insertion devices (IDs) is of utmost importance. Disturbances due to ground motion could result in unwanted broad-bandwidth beam-jitter which decreases the electron (and resultant photon) beam`s effective brightness. Therefore, feedback techniques must be used. Operating over a frequency range of < 1- to > 100-Hz, a local feedback system will correct these beam-trajectory errors using the four bumps around IDs. This paper reviews how the state-variable feedback approach can be applied to real-time correction of these beam position and angle errors. A frequency-domain solution showing beam jitter reduction is presented. Finally, this paper reports results of a beam-feedback test at BESSY I.
Authors: Gilpatrick, J.D., Khan, S., Kraemer, D.
Language: English
Open Access status: green
Award: G797745481
OpenAlex ID: W91282589
FWCI:
Cites: 1
Cited by: 1