Use of fusion-welding techniques in fabrication of a superconducting-magnet thermal-shield system
Year: 1983
Type: article
Abstract: Success of the thermal shield system was demonstrated by the results of acceptance tests performed with the magnet and all its ancillary equipment. During these tests the thermal shield system was: (1) thermally cycled several times from 300/sup 0/K to 77/sup 0/K; (2) pressure cycled several times from 0 to 5 atmospheres; (3) operated for more than 500 hours at 77/sup 0/K and in a vacuum environment of less than 10/sup -5/ torr; (4) operated in a magnetic field up to 6.0 Telsa; (5) exposed to a rapidly collapsing magnetic field of more than 250 gauss per second; (6) drained of all LN/sub 2/ in a few minutes, without any weld failures. The successful (and relatively problem free) operation of the magnet system validates the choice of the welding processes used, as well as their execution in both shop and field environments.
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green