Work

Test-fuel power-coupling dependence on TREAT control-rod positions

Year: 1983
Type: article
Abstract: The Transient Reactor Test (TREAT) is a graphite moderated, UO/sub 2/ fueled test reactor located at the Idaho National Engineering Laboratory and operated by Argonne National Laboratory. Test fuel is placed in containment vessels in the center of the reactor and subjected to computer-controlled transient irradiations which can result in experimental fuel melting or even vaporizing. The reactor was designed to have a strong negative temperature coefficient and to operate adiabatically. Consequently large reactivity insertions, up to 6.2% ..delta..k/k, may be required during a transient as the core temperature increases as much as 570/sup 0/C. This reactivity insertion is accomplished typically over 10 to 20 seconds by hydraulically actuated transient control rods. Evaluation of empirical data has indicated that control-rod-position changes cause power-coupling changes during a transient and usually are the primary factor in determining the ratio of the transient-averaged to steady-state test-fuel power coupling.
Language: English
Field: Energy
Open Access status: green
OpenAlex ID: W98058154
FWCI:
Cites:
Cited by:
Related to: 10