Ion Exchange Solid Phase Extraction Coupled with Liquid Chromatography Tandem Mass Spectrometry for Determination of 8 Classes of Non-steroidal Anti-inflammatory Drugs Residues in Animal Tissues
Year: 2012
Type: article
Abstract: An ultraperformance liquid chromatography tandem mass spectrometric(UPLC-MS/MS) method was established for the simultaneous determination of residues of 8 classes of 14 non-steroidal anti-inflammatory drugs(NSAIDs) in animal tissues. The samples were extracted with acetonitrile-ethyl acetate(1 ∶ 1,V/V),defatted with n-hexane,and then purified by MCX solid phase extraction(SPE) cartridge. Analysis was carried out on UPLC-ESI-MS/MS working with multiple reaction monitoring mode with polarity switching. Limits of detection were between 3.0 μg/kg and 10.0 μg/kg,and limits of quantification were between 10.0 μg/kg and 25.0 μg/kg.At spiked levels of 10.0-1000.0 μg/kg,in bovine and swine muscle the recoveries were 62.9%-108.4% and 63.4%-117.0%,respectively,and relative standard deviations(RSD) of the method were less than 10% and 9%,respectively.
Authors: Ting HU, Tao PENG, Xiao-Juan LI, Dong-Dong CHEN, Han-Hui DAI, Yue-Ning ZHOU, Xi XIA, Shuang-Yang DING, Ai-Ling ZHU, Hai-Yang JIANG
Language: English
Subfield: Food Science
Domain: Life Sciences
Open Access status: hybrid
Estimated APC paid: $1,400
OpenAlex ID: W2350038539