Year: 2011
Type: article
Abstract: In the last few years the use of guided ultrasonic waves (GUWs) for the health monitoring of engineering structures increased rapidly, with the most recent studies focusing on the application of GUWs to complex structures or under varying environmental conditions. In fact, the health monitoring of complex structures is complicated because of reflections, scattering, and mode conversion. In addition, sensitivity to temperature and surface wetting can degrade the performance of a GUW-based structural health monitoring system.This thesis presents the results of an experimental investigation where GUWs and the Electro-mechanical Impedance (EMI) method were used for the health monitoring of a truss, which was part of a highway variable message structure removed from service and tested in laboratory. The monitoring strategy proposed here combines the advantages of GUWs and EMI with the extraction of defect-sensitive features to perform a multivariate diagnosis of damage. The effectiveness of the presented approach is tested by monitoring the propagation of waves along one of the main chords of the truss and by observing the onset and growth of two artificial cracks. The ability to diagnose the presence of these defects located around the welds that join two diagonal angular members to the chord is discussed.In the last portion of the thesis, the results from field application are presented. Two overhead sign support structures deployed along I-279 were monitored by using the proposed SHM methodology developed in laboratory.
Author: Xuan Zhu
Language: English
Subfield: Mechanics of Materials
Field: Engineering
Domain: Physical Sciences
Open Access status: green