Product
Help
Pricing
About
Jobs
Log in
Get started
Author
Add to collection
Philipp Mann
Observed names:
Mann, Philipp,
P Mann,
P. Mann
Institution:
German Cancer Research Center
Observed institutions:
German Cancer Research Center,
Heidelberg University,
Heidelberger Institut für Radioonkologie,
National Center for Tumor Diseases
ORCID:
0000-0002-2857-4861
Observed ORCID:
0000-0002-2857-4861
OpenAlex ID:
A5085239447
Investigation of the halo-artifact in 68Ga-PSMA-11-PET/MRI
2017
·
Thorsten Heußer
, Philipp Mann
, et al.
·
PLoS ONE
·
68
PDF
Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR‐guided radiotherapy
2016
·
Nina I. Niebuhr
, Wibke Johnen
, et al.
·
Medical Physics
·
64
3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantom
2016
·
P Mann
, M Witte
, et al.
·
Physics in Medicine and Biology
·
49
Measurement of isocenter alignment accuracy and image distortion of an 0.35 T MR-Linac system
2019
·
S Dorsch
, P Mann
, et al.
·
Physics in Medicine and Biology
·
41
PDF
End-to-end test of an online adaptive treatment procedure in MR-guided radiotherapy using a phantom with anthropomorphic structures
2019
·
A Elter
, S Dorsch
, et al.
·
Physics in Medicine and Biology
·
38
PDF
Validation of complex radiotherapy techniques using polymer gel dosimetry
2024
·
Christian P Karger
, Alina Elter
, et al.
·
Physics in Medicine and Biology
·
28
Feasibility of polymer gel-based measurements of radiation isocenter accuracy in magnetic fields
2018
·
S Dorsch
, P Mann
, et al.
·
Physics in Medicine and Biology
·
26
PDF
End-to-end test for fractionated online adaptive MR-guided radiotherapy using a deformable anthropomorphic pelvis phantom
2021
·
A Elter
, C Rippke
, et al.
·
Physics in Medicine and Biology
·
20
Compatibility of 3D printing materials and printing techniques with PAGAT gel dosimetry
2019
·
A Elter
, S Dorsch
, et al.
·
Physics in Medicine and Biology
·
20
PDF
Absolute dosimetry with polymer gels—a TLD reference system
2019
·
P Mann
, A Schwahofer
, et al.
·
Physics in Medicine and Biology
·
19
PDF
Technical Note: ADAM PETer – An anthropomorphic, deformable and multimodality pelvis phantom with positron emission tomography extension for radiotherapy
2020
·
Clarissa Gillmann
, Noa Homolka
, et al.
·
Medical Physics
·
13
PDF
Polymer gel-based measurements of the isocenter accuracy in an MR-LINAC
2019
·
S Dorsch
, P Mann
, et al.
·
Journal of Physics Conference Series
·
13
PDF
Development of phantom materials with independently adjustable CT- and MR-contrast at 0.35, 1.5 and 3 T
2021
·
A Elter
, E Hellwich
, et al.
·
Physics in Medicine and Biology
·
10
PDF
Feasibility of markerless fluoroscopic real-time tumor detection for adaptive radiotherapy: development and end-to-end testing
2020
·
P Mann
, M Witte
, et al.
·
Physics in Medicine and Biology
·
9
PDF
On the feasibility of absolute 3D dosimetry using LiF thermoluminescence detectors and polymer gels on a 0.35T MR-LINAC
2020
·
A Schwahofer
, P Mann
, et al.
·
Physics in Medicine and Biology
·
7
RSC: Gel dosimetry as a tool for clinical implementation of image-guided radiotherapy
2022
·
A Elter
, S Dorsch
, et al.
·
Journal of Physics Conference Series
·
6
PDF
Technical Note: On the feasibility of performing dosimetry in target and organ at risk using polymer dosimetry gel and thermoluminescence detectors in an anthropomorphic, deformable, and multimodal pelvis phantom
2021
·
Mathieu Marot
, Alina Elter
, et al.
·
Medical Physics
·
6
PDF
PAGAT gel dosimetry for everyone: gel production, measurement and evaluation
2021
·
A Elter
, S Dorsch
, et al.
·
Biomedical Physics & Engineering Express
·
5
Development and implementation of 3D-dosimetric end-to-end tests in adaptive radiation therapy of moving tumors
2017
·
Mann, Philipp
·
heiDOK (Heidelberg University)
·
5
PDF
Validation of 4D dose calculation using an independent motion monitoring by the calypso tracking system and 3D polymer gel dosimetry
2017
·
P Mann
, N Saito
, et al.
·
Journal of Physics Conference Series
·
3
PDF
Feasibility of polymer gel dosimetry measurements in a dynamic porcine lung phantom
2015
·
P Mann
, M Witte
, et al.
·
Journal of Physics Conference Series
·
3
PDF
Quantification and reduction of susceptibility artefacts for a quality assurance phantom in MRgRT
2020
·
E. Hellwich
, A. Elter
, et al.
·
Radiotherapy and Oncology
·
1
Absolute dosimetry with polymer gels – A TLD reference system
2019
·
A. Schwahofer
, P. Mann
, et al.
·
Radiotherapy and Oncology
·
1
Development of an anthropomorphic multimodality pelvis phantom for PET/MRI- and CTbased RT planning
2019
·
N. Homolka
, A. Pfaffenberger
, et al.
·
Radiotherapy and Oncology
·
1
PDF
Range assignment of protons in 18-oxygenated dosimetry gel using MR-PET imaging
2016
·
M. Runz
, A. Runz
, et al.
·
Physica Medica
·
1
Show more works
View as search
Works count:
40
Citation count:
457
H-index:
12
I10-index:
13
Year
Topic
Type