Product
Help
Pricing
About
Jobs
Log in
Get started
Keyword
Add to collection
cuff leak
Description:
Escape of air or fluid past or from an inflated medical-device cuff, especially an endotracheal tube cuff, compromising its seal.
Primary topic:
Airway Management and Intubation Techniques (64%)
Related topics:
Airway Management and Intubation Techniques (64%),
Respiratory Support and Mechanisms (13%),
Nosocomial Infections in ICU (7%)
OpenAlex ID:
keywords/cuff-leak
Blood pressure monitoring: Automated oscillometric devices
1991
·
Maynard Ramsey
·
The Journal of Clinical Monitoring
·
179
Endotracheal Tubes: Old and New
2014
·
Carl F Haas
, Richard M Eakin
, et al.
·
Respiratory Care
·
138
PDF
Impact of the New Cuff Design on Reliability of the AS800 Artificial Urinary Sphincter
1992
·
J. Keith Light
, J. Cris Reynolds
·
The Journal of Urology
·
102
Safety of Bedside Percutaneous Dilatational Tracheostomy in Obese Patients in the ICU
2000
·
Naresh G. Mansharamani
, Henry Koziel
, et al.
·
CHEST Journal
·
100
Effects of steroids on reintubation and post-extubation stridor in adults: meta-analysis of randomised controlled trials
2009
·
Samir Jaber
, Boris Jung
, et al.
·
Critical Care
·
81
PDF
Evaluation of cuffed tracheal tube size predicted using the Khine formula in children
2007
·
CAROLINE DURACHER
, EMMANUELLE SCHMAUTZ
, et al.
·
Pediatric Anesthesia
·
79
An integrated graphic data display improves detection and identification of critical events during anesthesia.
1997
·
Peter Michels
, Dietrich Gravenstein
, et al.
·
The Journal of Clinical Monitoring
·
76
Postal survey of cuffed or uncuffed tracheal tubes used for paediatric tracheal intubation
2001
·
Gilles A. Orliaguet
, Estelle Renaud
, et al.
·
Pediatric Anesthesia
·
69
The role of ultrasound in appropriate endotracheal tube size selection in pediatric patients
2017
·
Demet Altun
, Mukadder Orhan‐Sungur
, et al.
·
Pediatric Anesthesia
·
62
Continuous Pneumatic Regulation of Tracheal Cuff Pressure to Decrease Ventilator-associated Pneumonia in Trauma Patients Who Were Mechanically Ventilated
2021
·
Nicolas Marjanovic
, Matthieu Boisson
, et al.
·
CHEST Journal
·
51
PDF
Large Air Leak from an Endotracheal Tube due to a Manufacturing Defect
1997
·
B. M. F. Lewer
, Z. Karim
, et al.
·
Anesthesia & Analgesia
·
50
Tracheal Cuff Pressure Monitoring in the ICU: A Literature Review and Survey of Current Practice in Queensland
2014
·
C. R. Talekar
, A. A. Udy
, et al.
·
Anaesthesia and Intensive Care
·
45
PDF
Choice of cuff inflation medium during nitrous oxide anaesthesia
1999
·
V. Mitchell
, T. Adams
, et al.
·
Anaesthesia
·
41
Leakage of fluid around high‐volume, low‐pressure cuffs
2001
·
T. Asai
, K. Shingu
·
Anaesthesia
·
40
Pressure dynamics of endotracheal and tracheostomy cuffs
1973
·
WEN-HSIEN WU
, IL-TAIK LIM
, et al.
·
Critical Care Medicine
·
31
Endotracheal tube cuff-small important part of a big issue
2012
·
Shai Efrati
, Israel Deutsch
, et al.
·
Journal of Clinical Monitoring and Computing
·
28
The relationship among bronchial blocker cuff inflation volume, proximal airway pressure, and seal of the bronchial blocker cuff
1992
·
Jonathan L. Benumof
, Sheila D. Gaughan
, et al.
·
Journal of Cardiothoracic and Vascular Anesthesia
·
28
Ultrasonographic Measurement of Subglottic Diameter for Paediatric Cuffed Endotracheal Tube Size Selection: Feasibility Report
2017
·
Demet Altun
, Mukadder Orhan Sungur
, et al.
·
Türk anesteziyoloji ve reanimasyon derneği dergisi
·
26
PDF
Optimization of Endotracheal Tube Cuff Filling by Continuous Upper Airway Carbon Dioxide Monitoring
2005
·
Shai Efrati
, Yuval Leonov
, et al.
·
Anesthesia & Analgesia
·
26
Early and Late Outcome of Bedside Percutaneous Tracheostomy in the Intensive Care Unit
2002
·
Elizabeth A. Mittendorf
, Christopher R. Mchenry
, et al.
·
The American Surgeon
·
24
Complications secondary to endotracheal intubation in dogs and cats: A questionnaire-based survey among veterinary anaesthesiologists
2023
·
Moriz Ettore Klonner
, Svenja Springer
, et al.
·
Veterinary Anaesthesia and Analgesia
·
23
Anaesthetic staff cannot identify extremely high tracheal tube cuff pressures by palpation of the pilot balloon
2013
·
S.A. Michlig
·
British Journal of Anaesthesia
·
22
Association between off-hour presentation and endotracheal-intubation-related adverse events in trauma patients with a predicted difficult airway: A historical cohort study at a community emergency department in Japan
2016
·
Yuko Ono
, Takuya Sugiyama
, et al.
·
Scandinavian Journal of Trauma Resuscitation and Emergency Medicine
·
20
PDF
The Ohmmeter Identifies the Site of Fluid Leakage during Artificial Urinary Sphincter Revision Surgery
2015
·
John Patrick Selph
, Michael James Belsante
, et al.
·
The Journal of Urology
·
18
Effect of Applying Positive Pressure With or Without Endotracheal Suctioning During Extubation: A Laboratory Study
2014
·
Mauro F Andreu
, Iris G Salvati
, et al.
·
Respiratory Care
·
18
PDF
Show more works
View as search
Works count:
196
Citation count:
1,845
Year
Topic
Type