Product
Help
Pricing
About
Jobs
Log in
Get started
Keyword
Add to collection
dynamic arc model
Description:
A mathematical model of an electrical arc that represents its changing behavior in high-voltage insulation or power systems.
Primary topic:
Vacuum and Plasma Arcs (39%)
Related topics:
Vacuum and Plasma Arcs (39%),
High voltage insulation and dielectric phenomena (25%),
Power Systems Fault Detection (8%)
OpenAlex ID:
keywords/dynamic-arc-model
Dynamic arc modeling of pollution flashover of insulators under DC voltage
1993
·
R. Sundararajan
, R.S. Gorur
·
IEEE Transactions on Electrical Insulation
·
169
The pollution flashover on high voltage insulators
2008
·
Muhsin Tunay Gençoğlu
, Mehmet Cebeci
·
Electric Power Systems Research
·
121
Arc Effect on Single-Phase Reclosing Time of a UHV Power Transmission Line
2004
·
I.M. Dudurych
, T.J. Gallagher
, et al.
·
IEEE Transactions on Power Delivery
·
88
Role of non-soluble contaminants on the flashover voltage of porcelain insulators
1996
·
R. Sundararajan
, R.S. Gorur
·
IEEE Transactions on Dielectrics and Electrical Insulation
·
71
Secondary plasma in the gap of high-current vacuum arc: origin and resulting effects
2003
·
S.M. Shkol'nik
·
IEEE Transactions on Plasma Science
·
55
Effect of insulator profiles on DC flashover voltage under polluted conditions. A study using a dynamic arc model
1994
·
R. Sundararajan
, R.S. Gorur
·
IEEE Transactions on Dielectrics and Electrical Insulation
·
55
Computer-aided design of porcelain insulators under polluted conditions
1995
·
R. Sundararajan
, N.R. Sadhureddy
, et al.
·
IEEE Transactions on Dielectrics and Electrical Insulation
·
42
Synchronized Measurements-Based Algorithm for Short Transmission Line Fault Analysis
2015
·
Vladimir Terzija
, Gary Preston
, et al.
·
IEEE Transactions on Smart Grid
·
39
A New DC and AC Arc Fault Electrical Model
2010
·
Jonathan Andrea
, Patrick Schweitzer
, et al.
·
IEEE Holm Conference on Electrical Contacts (HOLM)
·
32
Dynamic modeling of AC arc development on ice surfaces
2004
·
Changiz Tavakoli Zaniani
·
Constellation (Université du Québec à Chicoutimi)
·
32
PDF
Novel wavefront detection and fault location method based on Hilbert-Huang transform for long HVDC transmission lines
2022
·
Xiaoguang Zhu
, Shurong Li
, et al.
·
Electric Power Systems Research
·
31
Synchronised Measurements Based Algorithm for Long Transmission Line Fault Analysis
2017
·
Vladimir A. Stanojevic
, Gary Preston
, et al.
·
IEEE Transactions on Smart Grid
·
31
Parameter Determination for Modeling System Transients—Part VI: Circuit Breakers IEEE PES Task Force on Data for Modeling System Transients of IEEE PES Working Group on Modeling and Analysis of System Transients Using Digital Simulation (General Systems Subcommittee)
2005
·
J.A. Martinez
, J. Mahseredjian
, et al.
·
IEEE Transactions on Power Delivery
·
31
Computation of AC flashover voltage of polluted HV insulators using a dynamic arc model
2008
·
M. T. Gencoglu
, M. Cebeci
·
European Transactions on Electrical Power
·
25
A new frequency domain method for the harmonic analysis of power systems with arc furnace
1997
·
Wu Ting
·
IET International Conference on Advances in Power System Control, Operation and Management (APSCOM)
·
24
Application of Dynamic Model to Flashover of Ice-covered Insulators
2007
·
I. Fofana
, M. Farzaneh
·
IEEE Transactions on Dielectrics and Electrical Insulation
·
22
Dynamic model to predict the characteristics of the electric arc around a polluted insulator
2019
·
Lyamine Ouchen
, Abdelhafid Bayadi
, et al.
·
IET Science Measurement & Technology
·
20
Problems of modeling an electrical arc with variable geometric dimensions
2013
·
A. Sawicki
·
PRZEGLĄD ELEKTROTECHNICZNY
·
18
Discrimination of arcing faults on overhead transmission lines for single-pole auto-reclosure
2012
·
Hassan Meyar-Naimi
, Saeed Hasanzadeh
, et al.
·
International Transactions on Electrical Energy Systems
·
18
Influence of Single and Multiple Dry Bands on Critical Flashover Voltage of Silicone Rubber Outdoor Insulators: Simulation and Experimental Study
2018
·
Arshad
, Muhammad Ali Mughal
, et al.
·
Energies
·
16
PDF
Modeling and Simulating of Single-phase Arc Grounding Fault in Non-effective Earthed Networks
2009
·
Gao Wei-guo
·
Dianli xitong zidonghua
·
16
Detection of Arcing Faults: Modelling, Simulation, Testing and Algorithms Aspects
2007
·
V. Terzija
, N.I. Elkalashy
, et al.
·
16
EMTP simulation and spectral domain features of a long arc in free air
2005
·
V.V. Terzija
, M. Popov
, et al.
·
International Conference and Exhibition on Electricity Distribution (CIRED)
·
16
A new proposed dynamic arc model for flashover performance of a non-uniform polluted insulator string under HVAC stress
2014
·
Emad H. El-Zohri
, H. Ziedan
, et al.
·
Electric Power Systems Research
·
15
Dynamic Arc Modeling Based on Computation of Couple Electric Field and Flow Field for High Voltage SF $_6$ Interrupter
2004
·
L. Xiaoming
, W. Erzhi
, et al.
·
IEEE Transactions on Magnetics
·
15
Show more works
View as search
Works count:
107
Citation count:
1,283
Year
Topic
Type