Product
Help
Pricing
About
Jobs
Log in
Get started
Keyword
Add to collection
insertion trauma
Description:
Physical damage to cochlear structures caused during placement of an electrode array in cochlear implant surgery.
Primary topic:
Hearing Loss and Rehabilitation (61%)
Related topics:
Hearing Loss and Rehabilitation (61%),
Airway Management and Intubation Techniques (12%),
Neuroscience and Neural Engineering (11%)
OpenAlex ID:
keywords/insertion-trauma
Comparative Study of Cochlear Damage With Three Perimodiolar Electrode Designs
2003
·
Adrien A. Eshraghi
, Nathaniel W. Yang
, et al.
·
The Laryngoscope
·
282
Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size,
2008
·
Stephen J. Rebscher
, Alexander Hetherington
, et al.
·
The Journal of Rehabilitation Research and Development
·
192
Impact of the Insertion Speed of Cochlear Implant Electrodes on the Insertion Forces
2011
·
Georgios Kontorinis
, Thomas Lenarz
, et al.
·
Otology & Neurotology
·
149
A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. I: Comparison of Nucleus banded and Nucleus Contour™ electrodes
2004
·
Peter Wardrop
, David Whinney
, et al.
·
Hearing Research
·
146
Deep electrode insertion and sound coding in cochlear implants
2014
·
Ingeborg Hochmair
, Erwin Hochmair
, et al.
·
Hearing Research
·
138
PDF
Banded Intracochlear Electrode Array: Evaluation of Insertion Trauma in Human Temporal Bones
1985
·
R. K. Shepherd
, B. C. Pyman
, et al.
·
Annals of Otology Rhinology & Laryngology
·
128
Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays
2000
·
M TYKOCINSKI
, L COHEN
, et al.
·
American Journal of Otolaryngology
·
118
A temporal bone study of insertion trauma and intracochlear position of cochlear implant electrodes. II: Comparison of Spiral Clarion™ and HiFocus II™ electrodes
2004
·
Peter Wardrop
, David Whinney
, et al.
·
Hearing Research
·
103
Anatomic Considerations of Cochlear Morphology and Its Implications for Insertion Trauma in Cochlear Implant Surgery
2009
·
Berit M. Verbist
, Luca Ferrarini
, et al.
·
Otology & Neurotology
·
93
Spatiotemporal pH dynamics following insertion of neural microelectrode arrays
2006
·
Matthew D. Johnson
, Olivia E. Kao
, et al.
·
Journal of Neuroscience Methods
·
93
Insertion trauma and recovery of function after cochlear implantation: Evidence from objective functional measures
2015
·
Bryan E. Pfingst
, Aaron P. Hughes
, et al.
·
Hearing Research
·
81
A Lubricated Nonimmunogenic Neural Probe for Acute Insertion Trauma Minimization and Long‐Term Signal Recording
2021
·
Yeontaek Lee
, Hyogeun Shin
, et al.
·
Advanced Science
·
77
PDF
Loss of residual hearing after cochlear implantation
1989
·
William J. Boggess
, Jane E. Baker
, et al.
·
The Laryngoscope
·
77
In vivo performance of a microelectrode neural probe with integrated drug delivery: Laboratory investigation
2009
·
Pratik Rohatgi
, Nicholas B. Langhals
, et al.
·
Neurosurgical FOCUS
·
70
PDF
Factors influencing neurotrophic effects of electrical stimulation in the deafened developing auditory system
2008
·
Patricia A. Leake
, Olga Stakhovskaya
, et al.
·
Hearing Research
·
47
Gum Elastic Bougie-guided Insertion of the ProSeal™ Laryngeal Mask Airway
2004
·
J. Brimacombe
, C. Keller
·
Anaesthesia and Intensive Care
·
43
Collagenase-Aided Intracortical Microelectrode Array Insertion: Effects on Insertion Force and Recording Performance
2008
·
Kunal J. Paralikar
, Ryan S. Clement
·
IEEE Transactions on Biomedical Engineering
·
35
Variations in cochlear duct shape revealed on clinical CT images with an automatic tracing method
2017
·
Annerie M. A. van der Jagt
, Randy K. Kalkman
, et al.
·
Scientific Reports
·
31
PDF
Measurement of Forces at the Tip of a Cochlear Implant During Insertion
2014
·
Scott A. Wade
, James B. Fallon
, et al.
·
IEEE Transactions on Biomedical Engineering
·
31
Anatomical Variations of the Human Cochlea Using an Image Analysis Tool
2023
·
Raabid Hussain
, Attila Frater
, et al.
·
Journal of Clinical Medicine
·
29
PDF
Surgery for the Safe Insertion and Reinsertion of the Banded Electrode Array
1987
·
G. M. Clark
, B. C. Pyman
, et al.
·
Annals of Otology Rhinology & Laryngology
·
29
The Insertion Results of a Mid-scala Electrode Assessed by MRI and CBCT Image Fusion
2018
·
Sini Sipari
, Matti Iso-Mustajärvi
, et al.
·
Otology & Neurotology
·
24
Acoustic Hearing After Murine Cochlear Implantation: Effects of Trauma and Implant Type
2015
·
Jonathan C. Kopelovich
, Barbara K. Robinson
, et al.
·
Annals of Otology Rhinology & Laryngology
·
20
Ease of Proseal Laryngeal Mask Airway Insertion and its Fibreoptic view after Placement using Gum Elastic Bougie: A Comparison with Conventional Techniques
2009
·
S. Taneja
, M. Agarwal
, et al.
·
Anaesthesia and Intensive Care
·
20
Rotational vs. standard smooth laryngeal mask airway insertion in adults.
2012
·
Dileep Kumar
, Mueenullah Khan
, et al.
·
PubMed
·
19
Show more works
View as search
Works count:
122
Citation count:
2,394
Year
Topic
Type