Product
Help
Pricing
About
Jobs
Log in
Get started
Keyword
Add to collection
missing cone
Description:
An unsampled conical region of spatial-frequency information in tomographic imaging, which can limit reconstruction resolution.
Primary topic:
Advanced Electron Microscopy Techniques and Applications (33%)
Related topics:
Advanced Electron Microscopy Techniques and Applications (33%),
Advanced Fluorescence Microscopy Techniques (17%),
Digital Holography and Microscopy (10%)
OpenAlex ID:
keywords/missing-cone
The orthogonal tilt reconstruction method: An approach to generating single-class volumes with no missing cone for ab initio reconstruction of asymmetric particles
2005
·
Andres E. Leschziner
, Eva Nogales
·
Journal of Structural Biology
·
107
Superresolution and convergence properties of the expectation-maximization algorithm for maximum-likelihood deconvolution of incoherent images
1998
·
José-Angel Conchello
·
Journal of the Optical Society of America A
·
107
Artifacts in computational optical-sectioning microscopy
1994
·
James G. McNally
, Chrysanthe Preza
, et al.
·
Journal of the Optical Society of America A
·
102
Three-dimensional imaging by optical sectioning in the aberration-corrected scanning transmission electron microscope
2009
·
G. Behan
, E. C. Cosgriff
, et al.
·
Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences
·
90
A least-squares method for determining structure factors in three-dimensional tilted-view reconstructions
1983
·
David A. Agard
, M.F. Moody
·
Journal of Molecular Biology
·
87
A dual path programmable array microscope (PAM): simultaneous acquisition of conjugate and non‐conjugate images
2001
·
R. Heintzmann
, Q. S. Hanley
, et al.
·
Journal of Microscopy
·
78
Three-dimensional radiographic imaging with a restricted view angle
1979
·
M. Y. Chiu
, H. H. Barrett
, et al.
·
Journal of the Optical Society of America
·
78
Analytic derivation of optimal imaging conditions for incoherent imaging in aberration-corrected electron microscopes
2008
·
Varat Intaraprasonk
, Huolin L. Xin
, et al.
·
Ultramicroscopy
·
71
Improved and isotropic resolution in tomographic diffractive microscopy combining sample and illumination rotation
2011
·
Stanislas Vertu
, Jens Flügge
, et al.
·
Open Physics
·
67
PDF
Richardson-Lucy/maximum likelihood image restoration algorithm for fluorescence microscopy: further testing
1989
·
Timothy J. Holmes
, Yi-Hwa Liu
·
Applied Optics
·
66
Local and global 3D noise power spectrum in cone‐beam CT system with FDK reconstruction
2011
·
Jongduk Baek
, Norbert J. Pelc
·
Medical Physics
·
63
PDF
A local shift‐variant Fourier model and experimental validation of circular cone‐beam computed tomography artifacts
2009
·
Steven Bartolac
, Rolf Clackdoyle
, et al.
·
Medical Physics
·
60
PDF
Electron crystallography of zeolites – the MWW family as a test of direct 3D structure determination
2005
·
Douglas L. Dorset
, Wieslaw J. Roth
, et al.
·
Acta Crystallographica Section A Foundations of Crystallography
·
60
PDF
Calculation of three-dimensional optical transfer function for a confocal scanning fluorescent microscope
1989
·
Shigeharu Kimura
, Chusuke Munakata
·
Journal of the Optical Society of America A
·
58
Three-dimensional transfer-function analysis of the tomographic capability of a confocal fluorescence microscope
1990
·
Osamu Nakamura
, Satoshi Kawata
·
Journal of the Optical Society of America A
·
53
Theoretical analysis of a rotating-disk partially confocal scanning microscope
1994
·
José-Angel Conchello
, Jeff W. Lichtman
·
Applied Optics
·
46
Effects of a Finite-sized Pinhole on 3D Image Formation in Confocal Two-photon Fluorescence Microscopy
1993
·
Min Gu
, C.J.R. Sheppard
·
Journal of Modern Optics
·
45
Three-Dimensional Imaging in Aberration-Corrected Electron Microscopes
2010
·
Huolin L. Xin
, David A. Muller
·
Microscopy and Microanalysis
·
40
Approximation of missing-cone data in 3D electron microscopy
1989
·
M. Barth
, R.K. Bryan
, et al.
·
Ultramicroscopy
·
39
Three-dimensional reconstructions from incomplete data: Interpretability of density maps at “atomic” resolution
1989
·
Robert M. Glaser
, Liang Tong
, et al.
·
Ultramicroscopy
·
37
Visualizing the Secondary Structure of Tubulin: Three-Dimensional Map at 4 Å
1997
·
Eva Nogales
, Sharon Grayer Wolf
, et al.
·
Journal of Structural Biology
·
36
Beyond Born-Rytov limit for super-resolution optical diffraction tomography
2017
·
JooWon Lim
, Abdul Wahab
, et al.
·
Optics Express
·
33
Effects of TOF Resolution Models on Edge Artifacts in PET Reconstruction From Limited-Angle Data
2020
·
Paul Gravel
, Yusheng Li
, et al.
·
IEEE Transactions on Radiation and Plasma Medical Sciences
·
28
Limited-Angle Three-Dimensional Reconstructions Using Fourier Transform Iterations And Radon Transform Iterations
1981
·
Kwok-Cheong Tam
, Victor Perez-Mendez
·
Optical Engineering
·
28
A Regularized Iterative Algorithm for Limited-angle Inverse Radon Transform
1983
·
M. Defrise
, C. de Mol
·
Optica Acta International Journal of Optics
·
27
Show more works
View as search
Works count:
113
Citation count:
1,872
Year
Topic
Type