Description:
Phantom design is the development of physical models that reproduce relevant properties of tissues, organs, or bodies for medical imaging and treatment testing.
Related topics:
Advanced Radiotherapy Techniques (19%),
Radiation Dose and Imaging (10%),
Medical Imaging Techniques and Applications (9%),
Advanced MRI Techniques and Applications (9%)
OpenAlex ID:
keywords/phantom-design
Poly(vinyl alcohol) cryogel phantoms for use in ultrasound and MR imaging
2004
·
K J M Surry
, H J B Austin
, et al.
·
Physics in Medicine and Biology
·
411
PDF
Multi–Detector Row CT Attenuation Measurements: Assessment of Intra- and Interscanner Variability with an Anthropomorphic Body CT Phantom
2007
·
Bernard A. Birnbaum
, Nicole Hindman
, et al.
·
Radiology
·
291
New diffusion phantoms dedicated to the study and validation of high‐angular‐resolution diffusion imaging (HARDI) models
2008
·
Cyril Poupon
, Bernard Rieul
, et al.
·
Magnetic Resonance in Medicine
·
216
PDF
Design and application of an assessment protocol for electromagnetic tracking systems
2005
·
Johann B Hummel
, Michael R. Bax
, et al.
·
Medical Physics
·
163
Objective assessment of image quality and dose reduction in CT iterative reconstruction
2014
·
J. Y. Vaishnav
, W. C. Jung
, et al.
·
Medical Physics
·
138
PDF
A phantom for standarization and quality control in spinal bone mineral measurements by QCT and DXA: Design considerations and specifications
1992
·
Willi A. Kalender
·
Medical Physics
·
114
Evaluation of 3D printing materials for fabrication of a novel multi-functional 3D thyroid phantom for medical dosimetry and image quality
2017
·
Moayyad Alssabbagh
, Abd Aziz Tajuddin
, et al.
·
Radiation Physics and Chemistry
·
103
Physical imaging phantoms for simulation of tumor heterogeneity in PET, CT, and MRI: An overview of existing designs
2020
·
Alejandra Valladares
, Thomas Beyer
, et al.
·
Medical Physics
·
90
PDF
Technical considerations for implementation of x-ray CT polymer gel dosimetry
2005
·
M Hilts
, A Jirasek
, et al.
·
Physics in Medicine and Biology
·
77
PDF
The design of anisotropic diffusion phantoms for the validation of diffusion weighted magnetic resonance imaging
2008
·
Els Fieremans
, Yves De Deene
, et al.
·
Physics in Medicine and Biology
·
72
PDF
Comprehensive phantom for interventional fluorescence molecular imaging
2016
·
Maria Anastasopoulou
, Maximilian Koch
, et al.
·
Journal of Biomedical Optics
·
66
PDF
Comparative power law analysis of structured breast phantom and patient images in digital mammography and breast tomosynthesis
2013
·
L. Cockmartin
, H. Bosmans
, et al.
·
Medical Physics
·
65
Aqueous paramagnetic solutions for MRI phantoms at 3 T:A detailed study on relaxivities
2017
·
Kalaivani THANGAVEL
, Emine Ülkü SARITAŞ
·
TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES
·
60
Heterogeneous Breast Phantom Development for Microwave Imaging Using Regression Models
2012
·
Camerin Hahn
, Sima Noghanian
·
International Journal of Biomedical Imaging
·
59
PDF
Design and implementation of a film dosimetry audit tool for comparison of planned and delivered dose distributions in high dose rate (HDR) brachytherapy
2013
·
Antony L Palmer
, Chris Lee
, et al.
·
Physics in Medicine and Biology
·
57
PDF
Beam hardening correction in CT myocardial perfusion measurement
2009
·
Aaron So
, Jiang Hsieh
, et al.
·
Physics in Medicine and Biology
·
56
The Role of Viscosity Estimation for Oil-in-gelatin Phantom in Shear Wave Based Ultrasound Elastography
2014
·
Ying Zhu
, Changfeng Dong
, et al.
·
Ultrasound in Medicine & Biology
·
52
Review of ultrasound elastography quality control and training test phantoms
2011
·
S Cournane
, A J Fagan
, et al.
·
Ultrasound
·
52
PDF
Lung corrections in photon beam treatment planning: are we ready?
1984
·
Colin G. Orton
, Peter M. Mondalek
, et al.
·
International Journal of Radiation Oncology*Biology*Physics
·
51
Two applications of solid phantoms in performance assessment of optical coherence tomography systems
2013
·
Mohammad R. N. Avanaki
, Adrian Gh. Podoleanu
, et al.
·
Applied Optics
·
48
A physical phantom for the calibration of three‐dimensional X‐ray microtomography examination
2006
·
E. PERILLI
, F. BARUFFALDI
, et al.
·
Journal of Microscopy
·
48
Organosilicon phantom for photoacoustic imaging
2015
·
Cinzia Avigo
, Nicole Di Lascio
, et al.
·
Journal of Biomedical Optics
·
46
PDF
An integrated research tool for X-ray imaging simulation
2003
·
D Lazos
, K Bliznakova
, et al.
·
Computer Methods and Programs in Biomedicine
·
46
The impact of phantom design and material‐dependence on repeatability and reproducibility of CT‐based radiomics features
2022
·
Yanjing Li
, Meral Reyhan
, et al.
·
Medical Physics
·
44
Evaluating the impact of scan settings on automatic tube current modulation in CT using a novel phantom
2016
·
Deborah Merzan
, Patrik Nowik
, et al.
·
British Journal of Radiology
·
44
Show more works
View as search
Works count:
644
Citation count:
4,539
Year
Topic