Product
Help
Pricing
About
Jobs
Log in
Get started
Keyword
Add to collection
R417A
Description:
A hydrofluorocarbon refrigerant blend used in vapor-compression refrigeration and heating, ventilation, and air-conditioning systems.
Primary topic:
Refrigeration and Air Conditioning Technologies (72%)
Related topics:
Refrigeration and Air Conditioning Technologies (72%),
Heat Transfer and Boiling Studies (22%)
OpenAlex ID:
keywords/r417a
Convective boiling of pure and mixed refrigerants: An experimental study of the major parameters affecting heat transfer
2008
·
A. Greco
·
International Journal of Heat and Mass Transfer
·
99
Experimental performance evaluation of a vapour compression refrigerating plant when replacing R22 with alternative refrigerants
2011
·
Vincenzo La Rocca
, Giuseppe Panno
·
Applied Energy
·
92
An evaluation of R22 substitutes performances regulating continuously the compressor refrigeration capacity
2003
·
C. Aprea
, R. Mastrullo
, et al.
·
Applied Thermal Engineering
·
60
Experimental comparison of R22 with R417A performance in a vapour compression refrigeration plant subjected to a cold store
2003
·
C. Aprea
, C. Renno
·
Energy Conversion and Management
·
53
Saturated flow boiling heat transfer: review and assessment of prediction methods
2018
·
Xiande Fang
, Fengting Zhuang
, et al.
·
Heat and Mass Transfer
·
51
Refrigeration plant exergetic analysis varying the compressor capacity
2003
·
C. Aprea
, F. de Rossi
, et al.
·
International Journal of Energy Research
·
51
PDF
Vapour condensation of R22 retrofit substitutes R417A, R422A and R422D on CuNi turbo C tubes
2009
·
José Fernández-Seara
, Francisco J. Uhía
, et al.
·
International Journal of Refrigeration
·
47
Prediction of thermophysical properties of mixed refrigerants using artificial neural network
2010
·
Arzu Şencan
, İsmail İlke Köse
, et al.
·
Energy Conversion and Management
·
46
Heat transfer enhancement and pressure drop performance for R417A flow boiling in internally grooved tubes
2015
·
Xiaoyan Zhang
, Jin Zhang
, et al.
·
Energy
·
45
A theoretical study of an innovative ejector enhanced vapor compression heat pump cycle for water heating application
2011
·
Xiaojuan Chen
, Yuanyuan Zhou
, et al.
·
Energy and Buildings
·
45
Comparison of R407C and R417A heat transfer coefficients and pressure drops during flow boiling in a horizontal smooth tube
2008
·
C. Aprea
, A. Greco
, et al.
·
Energy Conversion and Management
·
45
An analysis of the performances of a vapour compression plant working both as a water chiller and a heat pump using R22 and R417A
2003
·
C. Aprea
, R. Mastrullo
, et al.
·
Applied Thermal Engineering
·
45
Comparison of experimental pressure drop data for two phase flows to prediction methods using a general model
2007
·
Alfonso William Mauro
, Jesús Moreno Quibén
, et al.
·
International Journal of Refrigeration
·
43
Experimental comparison of the energy parameters of HFCs used as alternatives to HCFC-22 in split type air conditioners
2015
·
Vedat Oruç
, Atilla G. Devecioğlu
, et al.
·
International Journal of Refrigeration
·
41
Thermodynamic performance of air conditioners working with R417A and R424A as alternatives to R22
2015
·
Vedat Oruç
, Atilla G. Devecioğlu
·
International Journal of Refrigeration
·
41
A method to estimate the circulated composition in refrigeration and heat pump systems using zeotropic refrigerant mixtures
2001
·
A Johansson
, P Lundqvist
·
International Journal of Refrigeration
·
38
Thermophysical Properties of the Refrigerant Mixtures R417A and R417B from Dynamic Light Scattering (DLS)
2012
·
A. Heller
, M. H. Rausch
, et al.
·
International Journal of Thermophysics
·
35
Heat transfer characteristics for evaporation of R417A flowing inside horizontal smooth and internally grooved tubes
2008
·
Xiaoyan Zhang
, Xingqun Zhang
, et al.
·
Energy Conversion and Management
·
30
Exergy analysis of scroll compressors working with R22, R407C, and R417A as refrigerant for HVAC system
2009
·
Sivakumar Kalaiselvam
, Ragupathy Saravanan
·
Thermal Science
·
23
PDF
Thermodynamic analysis of Tesla turbine in Organic Rankine Cycle under two-phase flow conditions
2022
·
Yuan Zhang
, Shizhao Zhang
, et al.
·
Energy Conversion and Management
·
21
Comparative Analysis of Neural Network and Neuro-fuzzy System for Thermodynamic Properties of Refrigerants
2012
·
Arzu Şencan Şahin
, İsmail İlke Köse
, et al.
·
Applied Artificial Intelligence
·
19
PDF
Heat transfer and enhancement analyses of flow boiling for R417A and R22
2011
·
Xiaoyan Zhang
·
Experimental Thermal and Fluid Science
·
19
Performance of A R22 split-air-conditioner when retrofitted with ozone friendly refrigerants (R410A and R417A)
2012
·
Bukola Olalekan Bolaji
·
Journal of Energy in Southern Africa
·
17
Experimental investigation of the effects of different refrigerants used in the refrigeration system on compressor vibrations and noise
2021
·
Zafer CİNGİZ
, Ferzan KATIRCIOĞLU
, et al.
·
International Advanced Researches and Engineering Journal
·
15
PDF
On-site Experimental Study of HCFC-22 Substitution with HFCs Refrigerants
2012
·
Antonio Messineo
, Vincenzo La Rocca
, et al.
·
Energy Procedia
·
15
PDF
Show more works
View as search
Works count:
96
Citation count:
1,197
Year
Topic
Type