Product
Help
Pricing
About
Jobs
Log in
Get started
Keyword
Add to collection
suture pull-through
Description:
Suture pull-through is a surgical failure mode in which a suture cuts through or disengages from tissue under tension.
Related topics:
Hernia repair and management (20%),
Shoulder Injury and Treatment (15%),
Veterinary Orthopedics and Neurology (9%),
Surgical Sutures and Adhesives (8%),
Orthopedic Surgery and Rehabilitation (8%),
Knee injuries and reconstruction techniques (7%)
show all 6
OpenAlex ID:
keywords/suture-pull-through
Tendon Augmentation Grafts: Biomechanical Failure Loads and Failure Patterns
2006
·
F. Alan Barber
, Morley A. Herbert
, et al.
·
Arthroscopy The Journal of Arthroscopic and Related Surgery
·
209
Internal Hernia Formation after Laparoscopic Roux-en-Y Gastric Bypass for Morbid Obesity
2002
·
Jennifer E. Filip
, Samer G. Mattar
, et al.
·
The American Surgeon
·
111
Autologous, cadaveric, and synthetic materials used in sling surgery: comparative biomechanical analysis
2001
·
Jong M Choe
, Rupa Kothandapani
, et al.
·
Urology
·
95
Endothelial Keratoplasty: The Influence of Insertion Techniques and Incision Size on Donor Endothelial Survival
2008
·
Mark A Terry
, Hisham A Saad
, et al.
·
Cornea
·
93
High‐Tensile Strength Tape Versus High‐Tensile Strength Suture: A Biomechanical Study
2015
·
Ryan J. Gnandt
, Jennifer L. Smith
, et al.
·
Arthroscopy The Journal of Arthroscopic and Related Surgery
·
70
Iatrogenic vascular injuries from percutaneous vascular suturing devices
2001
·
Mark R. Nehler
, W.Andrew Lawrence
, et al.
·
Journal of Vascular Surgery
·
65
PDF
Experimental study of the characteristics of a novel mesh suture
2015
·
G A Dumanian
, A Tulaimat
, et al.
·
British journal of surgery
·
62
PDF
Biomechanical Comparison of 3 Novel Repair Techniques for Radial Tears of the Medial Meniscus: The 2-Tunnel Transtibial Technique, a “Hybrid” Horizontal and Vertical Mattress Suture Configuration, and a Combined “Hybrid Tunnel” Technique
2019
·
Patrick S. Buckley
, Bryson R. Kemler
, et al.
·
The American Journal of Sports Medicine
·
52
Biomechanical comparison of anterior cruciate ligament repair with internal brace augmentation versus anterior cruciate ligament repair without augmentation
2020
·
Patrick Massey
, David Parker
, et al.
·
Clinical Biomechanics
·
50
PDF
Mesh Sutured Repairs of Abdominal Wall Defects
2016
·
Steven T. Lanier
, Gregory A. Dumanian
, et al.
·
Plastic & Reconstructive Surgery Global Open
·
50
Alendronate prevents bone loss and improves tendon‐to‐bone repair strength in a canine model
2007
·
Stavros Thomopoulos
, Hironori Matsuzaki
, et al.
·
Journal of Orthopaedic Research®
·
50
PDF
In Vivo Evaluation of a Novel Mesh Suture Design for Abdominal Wall Closure
2015
·
Jason M. Souza
, Zari P. Dumanian
, et al.
·
Plastic & Reconstructive Surgery
·
46
PDF
The influence of cross-sectional area on the tensile properties of flexor tendons
2001
·
Martin I. Boyer
, Matthew J. Meunier
, et al.
·
The Journal Of Hand Surgery
·
46
Force Sensing in Surgical Sutures
2013
·
Tim Horeman
, Evert-jan Meijer
, et al.
·
PLoS ONE
·
45
PDF
Tensile Strength of Cadaveric Fascia Lata Compared to Small Intestinal Submucosa Using Suture Pull Through Analysis
2001
·
WILLIAM S. KUBRICHT
, B. JILL WILLIAMS
, et al.
·
The Journal of Urology
·
32
Comparison of a multifilament stainless steel suture with FiberWire for flexor tendon repairs — an in vitro biomechanical study
2012
·
E. McDonald
, J. A. Gordon
, et al.
·
Journal of Hand Surgery (European Volume)
·
29
Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair
2018
·
Mohamed M. Ibrahim
, Luke P. Poveromo
, et al.
·
Journal of Biomechanics
·
28
The role of graft materials in suture augmentation for tendon repairs and reattachment
2005
·
Frederick J. Kummer
, Kazuho Iesaka
·
Journal of Biomedical Materials Research Part B Applied Biomaterials
·
26
Biomechanical Testing of a Novel Suture Pattern for Repair of Equine Tendon Lacerations
2011
·
Eric Everett
, Jennifer G. Barrett
, et al.
·
Veterinary Surgery
·
25
Effect of bite depth of an epitendinous suture on the biomechanical strength of repaired canine flexor tendons
2019
·
Daniel J. Duffy
, Yi-Jen Chang
, et al.
·
American Journal of Veterinary Research
·
24
Biomechanical Properties of a Novel Mesh Suture in a Cadaveric Flexor Tendon Repair Model
2019
·
Stephen J. Wallace
, Lauren M. Mioton
, et al.
·
The Journal Of Hand Surgery
·
21
Suturable mesh better resists early laparotomy failure in a cyclic ball-burst model
2020
·
C. J. Scheiber
, S. S. Kurapaty
, et al.
·
Hernia
·
20
Retropubic long-needle suspension procedures for stress urinary incontinence
1990
·
R. Edward Varner
·
American Journal of Obstetrics and Gynecology
·
19
Duramesh registry study: short-term outcomes using mesh suture for abdominal wall closure
2024
·
Paige N. Hackenberger
, Mehul Mittal
, et al.
·
Frontiers in Surgery
·
18
PDF
What is the best way to fix a polyurethane meniscal scaffold? A biomechanical evaluation of different fixation modes
2013
·
Francois Hardeman
, Kristoff Corten
, et al.
·
Knee Surgery Sports Traumatology Arthroscopy
·
18
Show more works
View as search
Works count:
119
Citation count:
1,666
Year
Topic
Type