Combined Turbulent Convection Heat Transfer to Near Critical Water
Year: 1966
Type: report
Abstract: bulk water temperatures ranged from 606 deg F to saturation temperathres, and the Reynolds number in the test section varied between 207,000 and 475,000. Local property values, heat transfer parameters and selected dimensionless ratios were computed for each of thirteen positions along the lengih of the test section. Heat transfer coefficients, based on bulk fluid temperature, were found to range from 6500 to 53,000 B/hr ft/sup 2/ F, and reached a peak of 107,000 B/hr ft/sup 2/ F at the transition poirt in a two phase film boiling run. It was found that all single phase subcooled heat transfer data could be successfully correlated, in turn, by the well known Dittus-Boelter, SiederTate, Colburn and Prandtl equations. An empirical correlation equation, developed from the Prandti equation, successfully correlated the experimental subcooled single phase, subcooled boiling, and low quality nucleate boiling data. (P.C.H.)
DOI: 10.2172/4563206
Authors: R.F. Touba, P.W. McFadden
Language: English
Subfield: Computational Mechanics
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W168907668