Analytical results for 328 water samples from the Silver City 1° x 2° quadrangle, Arizona and New Mexico
Year: 1983
Type: report
Abstract: SAMPLING METHODSThe 328 water samples were collected from 248 wells, 15 springs and seeps, and 51 storage tanks that were fed by either wells or springs at that site.The remaining 14 samples were "duplicate" samples; this "duplication" occurred when a well-water sample was taken from a well that fed a previously sampled storage tank.Well-water samples were taken from dug wells, windmills, irrigation and domestic wells.Samples from pumping wells were taken as close to the well head as possible.Generally, wells were allowed to run for 3-5 minutes before the sample was taken, although intermittent wind conditions sometimes forestalled that precautionary procedure.Water from wells having pressure t$nks was collected, when possible, before the water reached the tank.Water from the pressure tank was allowed to run 1-5 minutes (depending on size and frequency of use of the pressure tank) after pumping began.The influx of "fresh" water was generally indicated by a sharp drop in temperature.These samples were also classified well-water samples.Water was taken from storage tanks when such factors as lack of wind, access to electricity, physical barriers, and so forth, prohibited the taking of water from a pumping well.These tanks were constructed from a variety of materials including cement, concrete, wood, iron, and galvanized zinc.The interiors of some tanks were coated with asphalt, asphalt-asbestos mixtures, and aluminum paint.Some of the springs and seeps were "improved", but water was classified tank water only if the water was taken from a separate holding tank.At each sample site, a portion of the water was filtered through a 0.45micron filter and collected into an acid-rinsed polyethylene bottle.This sample was immediately acidified to pH<2 by the addition of a few drops of Ultrex nitric acid.Additionally, a portion of untreated water was collected into a polyethylene bottle that had been rinsed with the sample water.At 103 well and 5 spring sites, an untreated sample was collected into a glass bottle having a foil-lined cap for later radon determination. the year the sample was collected.The next two letters indicate the 7.5-or 15-minute U.S.
DOI: 10.3133/ofr8384
Authors: Jerry R. Hassemer, W. H. Ficklin, J. M. Motooka, K. C. Watts, David J. Preston, S. M. Smaglik, F. N. Ward
Language: English
Subfield: Water Science and Technology
Field: Environmental Science
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W17359335
