Work

Reduction Of Noise And Over-Compression Loss By Scroll Compressor With Modified Discharge Check Valve

Year: 2002
Type: conference-paper
Abstract: In this report, we will explain our development of an optimum discharge check valve structure used in scroll compressors, based on a simplified model calculation and an experiment.We found that the behavior of check valve in the calculation analysis was consistent with actual valve behaviors if only we apply damping coefficient and adhesive strength at the face of valve seat/valve retainer as experiment constants, even though the model is a simple one that uses the pressure change equation derived from the first law of thermodynamics, the compressive onedimensional flow equation and the valve motion equation.Based on this method, we have accomplished a chattering noise reduction and over-compression loss reduction by modifying the shapes of scroll wrap, discharge port, valve and valve retainer, without losing the fundamental function of preventing reverse rotation on compressor shutdown.
Authors: Toshiyuki Toyama, Yuri Nishikawa, Yoshiaki Yoshida, S. Hiodoshi, Y. Shibamoto
Language: English
Open Access status: green
OpenAlex ID: W18692011
FWCI:
Cites: 2
Cited by: 3
Related to: 9