Year: 2015
Type: article
Abstract: A polymer‐based flat heat pipe (PFHP) was fabricated. The heat transfer performance was measured and analyzed when deionized (DI) water and acetone were used as the working fluid, separately. Input power ranging from 2.8 W to 14.2 W was provided to the evaporator section while the device was at different filling ratios. Experimental results revealed that, when the polymer‐based flat heat pipe was laid in a horizontal position, the thermal resistance (1.02 K/W) was much smaller than that (4.6 K/W) of a copper plate with the same thickness at the thermal power of 10.3 W and the value decreased as the tilt angle changed from 0° to 90°.
Source: Heat Transfer-Asian Research
DOI: 10.1002/htj.21187
Authors: Bo Shi, Yi‐Biao Wang, Ying‐Jie Shan
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: bronze
Award: G7253553062
OpenAlex ID: W1908795521