Safe oxygen saturation targeting and monitoring in preterm infants: can we avoid hypoxia and hyperoxia?

Year: 2014
Type: review
Abstract: UNLABELLED: Oxygen is a neonatal health hazard that should be avoided in clinical practice. In this review, an international team of neonatologists and nurses assessed oxygen saturation (SpO2 ) targeting in preterm infants and evaluated the potential weaknesses of randomised clinical trials. CONCLUSION: SpO2 of 85-89% can increase mortality and 91-95% can cause hyperoxia and ill effects. Neither of these ranges can be recommended, and wider intermediate targets, such as 87-94% or 88-94%, may be safer.
Language: English
Field: Medicine
Open Access status: hybrid
Estimated APC paid: $4,480
OpenAlex ID: W1980469766
FWCI: 2.255
Cites: 72
Cited by: 129
Related to: 10