Study on particles distribution characteristics through a circulation fluidized bed with the spiral flow generator
Year: 2012
Type: conference-paper
Abstract: A particle distribution test system of liquid-solid horizontal circulating fluidized bed was designed. The CCD image measurement and data processing system was used to study the particles distribution at different operating conditions of single pipe horizontal circulating fluidized bed with the spiral flow generator. Experimental results show that the spiral pipe flow generator with an appropriate angle, which is properly placed in the liquid-solid horizontal circulating fluidized bed, can effectively improve the uniform distribution of particles in the upper part, and decrease the non-uniform distribution of particles in the pipe. The installation position has a significant impact to the particles distribution. With the liquid flow rate enhanced, cross-section of axial position of the non-uniform distribution of particles decreased and the impact from swirl flow intensified. It provides some theoretical information for the ptimal design of the engineering.
Source: Energy Procedia
Authors: Yan Liu, Shaofeng Zhang, Wei Zhang
Institution: Hebei University of Technology
Language: English
Subfield: Computational Mechanics
Field: Engineering
Domain: Physical Sciences