Work

Internal reversible hydrogen embrittlement leads to engineering failure of cold drawn wire

Year: 2013
Type: article
Abstract: • Wire breakages during drawing operation leads to heavy loss. • Failure investigation of wire samples is essential for understanding the problem. • These present paper highlights failure investigation of wires during operations. • The experiment confirms that the failure is due to hydrogen embrittlement.
Institution: Tata Steel (India)
Language: English
Open Access status: hybrid
OpenAlex ID: W1998459216
FWCI: 1.025
Cites: 4
Cited by: 14
Related to: 10